Radvt-Ift Wiring Requirements - Vermont Castings Radiance RADVT Series Installation & Operating Manual

Direct vent gas heater
Table of Contents

Advertisement

F. RADVT-IFT Wiring Requirements
Intellifire™ Touch Ignition System Wiring
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IFT controlled appliance junction box to a switched circuit.
Incorrect wiring will override IFT safety lockout.
• Refer to Figure 3.26, IFT Wiring Diagram.
• This appliance is equipped with an Intellifire™ Touch
control valve which operates on a 6 volt/1.5 AMP system.
• Plug the 6 volt transformer plug into the appliance
junction box to supply power to the unit OR install 4 AA
cell batteries (not included) into the battery pack before
use.
Figure 3.26 - RADVT-IFT Wiring Diagram
2424
FLAME
SENSE
IFT-RC400
REMOTE
CONTROL
S
RF MODULE
ROCKER
SWITCH
BRN
BLK
Vermont Castings • Radiance RADVT Installation Manual_R4 • 04/19
NOTICE: Batteries should only be used as a power source in
the event of an emergency power outage. Batteries should
not be used as a primary long-term power source. Battery
polarity must be correct when installing batteries. When
using batteries as a power source, the 6-volt transformer
must be unplugged from the receptacle.
Do not store batteries in the battery pack when the
appliance is powered by the 6 volt transformer connected to
permanent electrical service.
Accessories Requirements
• This appliance ships standard with a remote control.
Wiring for optional Hearth & Home Technologies
approved accessories should be done now to avoid
reconstruction. Follow instructions that come with those
accessories.
IGNITER
TO JUNCTION
BOX 110-120 VAC
I
GROUND
3 PRONG 110VAC
6 PIN
BLK
RED
RED
BLK
BLK
SPLITTER
FAN
6V DC
BATTERY PACK
3-90-30007498