Page 2
The data in this document may not be altered or amended without special noti- fication from ETAS GmbH. ETAS GmbH undertakes no further obligation in relation to this document. The software described in it can only be used if the customer is in possession of a general license agreement or single license.
(serious) injury, if not avoided. CAUTION identifies a hazard with low risk that could result in minor or medium physical injuries or property damages if not avoided. ES413.1 - User’s Guide...
(see chapter 9.1 on page 84). Additional cables and adapters can be obtained separately from ETAS. A list of available accessories and their order designation is located in chapter “Acces- sories” on page 85 of this manual or in the ETAS product catalog.
“Intended Use” on page 9 General Safety Information Please observe the Product Safety Notices ("ETAS Safety Notice") and the fol- lowing safety notices to avoid health issues or damage to the device. Carefully read the documentation (Product Safety Advice and this User's Guide) that belongs to the product prior to the startup.
Page 10
The power cable may not be connected directly to the vehicle battery or the lab power supply, but only via a suitable fuse. • Ensure that the connections of the lab power supply, the power supply at the module and the vehicle battery are easily accessible! ES413.1 - User’s Guide...
Page 11
• Adhere to the maximum permissible cable lengths! • Do not use any damaged cables! Cables may be repaired only by ETAS! CAUTION Never apply force to insert a plug into a socket. Ensure that there is no contamination in and on the connection, that the plug fits the socket, and that you correctly aligned the plugs with the connection.
Page 12
• the temperature resistance of the modules (for example, do not install modules on the motor, turbocharger, exhaust manifold or their environ- ments). CAUTION During the installation of the modules, observe the permissible temperature range of the cable ties being used! ES413.1 - User’s Guide...
Page 13
Maintenance The product is maintenance-free. Repair If a repair of an ETAS hardware product should become necessary, send the product to ETAS. Cleaning the module housing • Use a dry or lightly moistened, soft, lint-free cloth for cleaning the module housing.
Fig. 3-1 Central and Decentral Sensor Cabling With the ES400 modules, ETAS provides a decentral solution which consider- ably simplifies the test setup of the sensors. The basic idea of this concept is to install the modules of the ES400 family as close as possible to the sensors, to concatenate the modules with each other and to connect just the first module of this chain with the laptop in the vehicle.
Each module has an LED for localizing the module. • The A/D Module with Sensor Supplys of the ES400 family use a XCP- based protocol which is compatible to the existing ETAS Ethernet topol- ogy. The concept fulfills the following requirements: –...
Data” on page 57. Housing A sturdy metal housing is used for the ES413.1; it has ports on the front of the device so it can fit into tight spaces. The ES413.1 is specifically designed to be installed in engine compartment, but also in the passenger cell.
Lemo connectors. 3.4.1 Sensor Connection Cable The front of the ES413.1 features a integrated sensor connection cable to which four sensors can be connected. An individual sensor power supply port is available for each sensor.
ETAS ES400 Product Family Fig. 3-3 ES413.1-OW (top left), ES413.1-L0B (top right) und ES413.1-L1B (bottom left) 3.4.2 Daisy Chain Ports (“IN”, “OUT”) The modules are connected using a daisy chain topology. This means each module has an explicit input socket and an explicit output socket. The Ethernet...
Functional State Display State yellow-red flashing Warning 0,5 s yellow reduced / Overload on a sensor supply 0,5 s red reduced voltage channel red illuminated Error during self-test fully bright red illuminated Internal error semi bright ES413.1 - User’s Guide...
Features of the ES413.1 Fig. 4-1 ES413.1 Housing The ES413.1 A/D Module with Sensor Supply is a member of the family of ES400-Modules. The ES413.1 can acquire analog voltages at four input chan- nels. There is a sensor supply for every channel.
Detection Fig. 4-2 Block Diagram The ES413.1 is a module with four identical sensor channels, two shared Ether- net interfaces, a power supply and a integrated sensor connection cable. The integrated sensor connection cable consists of four identical cable sec- tions in different length to which four sensors can be connected.
7.8.5 on page 66. 4.3.1.3 Digital Filter Configuration Recommendations The -3 dB cutoff frequency of the digital filter system of the ES413.1 can be configured in the application program. To avoid aliasing effects, be sure to observe recommendations for the configu- ration of the filter depending on the selected INCA sampling rate.
Hardware Description 4.3.4 Sensor Supply Every sensor that can be switched to the ES413.1 has an individual sensor sup- ply voltage which can be set separately. The integrated integrated sensor connection cable transfers both the sensor supply voltage and the sensor output voltage for the sensor. Additional cables or an additional external power supply for the sensor supply voltage are not required.
Message Format “XCP on UDP” (Schematic) Using the UDP/IP standard for data transfer makes it possible to connect the modules directly to a PC, a router or a switch. In XCP communication, the PC has the master function. ES413.1 - User’s Guide...
The communication protocol used by the ES400 family makes it possible for third-party suppliers to use the communication protocol for their own, non- ETAS applications once the modules have been configured with the „ES4xx Configuration Tool from ES4xx_DRV_SW“ . 4.4.2 Realization 4.4.2.1...
Page 27
IEEE1588 (Precision Time Protocol). The modules add the time stamp to the Ethernet data package for every measure date. The combination of time stamp synchronization, full duplex and time slice pro- cedure results in a very high reference data rate of the modules. ES413.1 - User’s Guide...
4.4.3 Examples 4.4.3.1 Example 1 Fig. 4-7 on page 28 shows an example of an application with three concatenated ES400 modules with the same acquisition rates. The transfer scheme for this configuration is shown in Fig. 4-8 on page 28. MODUL 1 M ODUL 2 M ODUL 3...
4.4.3.2 Example 2 Fig. 4-9 on page 29 shows an example in which three modules with different acquisition rates are linked to each other. The transfer scheme for this configuration is shown in Fig. 4-10 on page 29. MODUL 1 M ODUL 2 M ODUL 3 Stellgrößen...
ES400 modules with supply voltages between 5 V and 50 V DC over the entire temperature range. With the power supply management of the ES413.1, you can use an automatic power-saving feature (“Standby”) as well as a “Wake Up” function via the Ether- net interface.
Page 31
ETAS Example 1: For module chains which are equipped exclusively with ES410.1 or ES441.1, ETAS recommends the use of Y boost cables if the length of the module chain is longer than 10 modules. Example 2: For module chains which are equipped exclusively with ES411.1 or ES413.1 or ES421.1, ETAS recommends the use of Y boost cables if the length of the mod-...
Page 32
With a minimum voltage of 9 V, no additional feeding is necessary with a Y cable if the module chain consists of the following modules: • five ES420.1 or ES421.1 and • two ES415.1 (with sensor feeding) and • one ES441.1 All examples apply at 85 °C ambient temperature. ES413.1 - User’s Guide...
ETAS Configuration The configuration of the ES413.1 is performed entirely via the GUI within INCA. The configuration of the individual channels is saved either in INCA or in the individual ES400 modules. In the first case, you can prepare settings for spe- cific measure tasks, e.g.
CAUTION Potential equalization in the vehicle over the shield of the Ethernet connecting cables of modules may occur! Mount the modules only to components with the same electrical potential or insulate the modules from the components. ES413.1 - User’s Guide...
The module then loses the features defined by IP65. Assembly ES413.1 and ES421.1-K modules you can mechanically interlink or connect onto other components. You need additional parts (srews or threaded rods with nuts, cable fasteners etc.) to assemble the modules.
Here, you connect a number of ES400 modules (housing with through holes) with each other using two additional screws or threaded rods with nuts inserted through the holes. The through holes have a diameter of 4 mm and a length of 40 mm. ES413.1 - User’s Guide...
Every module base has openings for two cable fasteners each on the right- and left-hand side (see Fig. 5-5 on page 37). Just use cable fasteners to quickly attach the modules to other components in the test environment in the imme- diate proximity of the measuring points. ES413.1 - User’s Guide...
ETAS Getting Started CAUTION When assembling the modules, observe the admissible temperature range of the cable fasteners used! Drilling Template Fig. 5-6 Drilling Template ES413.1 - User’s Guide...
ES413.1 with additional ETAS Modules for MC Applications The ETAS Daisy Chain concept enables a simple network architecture since only the ES413.1 or the first module of the module chain is connected with the PC or with the "ETH" port of the ES59x.1.
1 Type per Module Vehicle, Test Bench, Motor, ... Fig. 5-8 ES413.1 with ES910.3 and additional ETAS Modules for Rapid Prototyping Applications The concept of the ES4xx/ES63x/ES93x product family to install the modules as close as possible to the sensors, the chain the modules with each other, and to connect only the first module of this chain with the ES910.3 or the RTPRO-...
ES595 ES411 ES413 ES420 ES430 ES415 ES421 ES432 ES441 ES410 Fig. 5-9 ES400 Modules with additional ETAS Modules (Measurement and Calibration) Cable in Function Order name Fig. 5-9 Power supply cable CBP120, CBP1205 Host connection cable CBE100 Power supply and Ethernet cable Daisy Chain...
Tempera- Frequency, Exhaust Voltage ture Counter Results, Pressure Times Fig. 5-10 ES400 Modules with additional ETAS Modules and Drive Recorder (Measurement and Calibration) Cable in Function Order name Fig. 5-10 ES520-, ES59x-, ES6xx-, ES1120- or ES1135- CBE130, CBE140 Ethernet cable...
Cable in Function Order name Fig. 5-12 Ethernet adapter cable (100 Mbit/s) CBAE330 (con- nected to cable Ethernet connection cable(1 Gbit/s) CBE230 (con- nected to cable Power supply and Ethernet cable Daisy Chain CBEP430, modules CBEP4305 ES413.1 - User’s Guide...
ES413.1-L1B If you have swapped IPETRONIK "M-SENSE 4" modules for ES413.1-L1B mod- ules in your test set-up, this ES413.1 version allows you to continue to use the wiring you have used to date for your test set-up. To wire the ES413.1 with the sensors 1.
To wire the first module with the PC and the power supply 1. Connect the combined Ethernet and power supply cable to the “IN” port of the ES413.1. 2. Connect the RJ-45 connector to the free Ethernet interface port of your PC.
Page 48
Addit ional Pow er Supply 3. Connect the combined Ethernet and power supply cable to the “IN” port of the ES413.1 of the next module towards the end of the chain. 4. Connect the supply voltage connector of the combined Ether- net and power supply cable to the desired power supply.
LED Displays Please observe the LEDs which provide information on the functions of the interface and the ES413.1 (see the chapter “LED” on page 19) to be able to judge the operational state of the ES413.1 as well as troubleshooting mea- sures.
Page 50
Are you using WLAN in your WLAN is not permissible within this data transfer. test setup? ETAS network. Wire your test setup (ETAS modules and their connection to the PC) with ETAS cables only. Are you using the correct Check whether you are using a PCMCIA type of network card in your network card in your laptop.
Windows 7, 8.1 and 10 systems. Network security policies, however, may request the APIPA mechanism to be disabled. In this case, you cannot use a network adapter which is configured for DHCP to access ETAS hardware. The ETAS Network Manager displays a warning message.
Whenever you switch from a DHCP company LAN to the ETAS hardware net- work, it takes at least 60 seconds until ETAS hardware can be found. This is caused by the operating system’s switching from the DHCP protocol to APIPA, which is being used by the ETAS hardware.
Page 53
Cause: Automatic disruption of network connection It is possible after a certain period of time without data traffic that the network card automatically interrupts the Ethernet connection. This can be prevented by setting the registry key autodisconnect. ES413.1 - User’s Guide...
Ethernet hardware at all, although the configuration parameters are correct. Some actions in ETAS products can lead to problems if the firewall is not prop- erly parameterized, e.g. when opening the experiment environment in ASCET or for the hardware search by INCA or HSP.
Page 55
ETAS • Outgoing TCP/IP connections to the network configured for the ETAS application, destination ports 18001 to 18020 The ports to be used in a specific case depend on the hardware used. For more detailed information about the port numbers to be used, see the respective hardware documentation.
Page 56
*.ini files are modified during the work. The ETAS software must be installed by an administrator in any case. It is rec- ommended that the administrator ensures that the ETAS product or the pro- cesses are added to the list of selected exceptions of the Windows Firewall after the installation.
Connection of sensor cable SN: 1234567 Serial number (seven-digit) Vx.y.z Hardware version of the product F 00K 123 456 Ordering number of the product, see chapter 9.1 on page 84 Operating voltage range (DC), Power consumption ES413.1 - User’s Guide...
WARNING This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. ES413.1 - User’s Guide...
7.1.4 Maintenance the Product Do not open or change the module! Works on the module housing may be exe- cuted only by qualified technical personnel. Send defect modules to ETAS. 7.1.5 Cleaning the product We recommend to clean the product with a dry cloth.
RoHS label attached to the product or its packaging. CE Marking With the CE mark attached to the product or its packaging, ETAS confirms that the product corresponds to the product-specific, applicable European Direc- tives. The CE Declaration of Conformity for the product is available upon request.
Some products from ETAS GmbH (e.g. modules, boards, cables) use compo- nents with substances that are subject to declaration in accordance with the REACH regulation (EU) no.1907/2006. Detailed information is located in the ETAS download center in the customer information "REACH Declaration" (www.etas.com/Reach). This information is continuously being updated.
"Allow the computer to turn off this device to save power". 7.7.2 Software To configure the ES413.1 and for control and data acquisition, you need soft- ware in the following versions: • INCA V6.2.1 and higher with INCA-ES4xx Add-On V1.1.12 and higher •...
Polarity inversion protection, load With CBEP410, CBEP4105, CBEP415, dump protection CBEP4155, CBEP420, CBEP4205, CBEP425, CBEP4255, CBEP430, CBEP4305 cable : The module may be used only with central load dump protection. ES413.1 - User’s Guide...
-1 V to +1 V -10 V to +10 V -60 V to +60 V Maximum input voltage Input-to-input: 60 V DC / 30 V AC Input-to-ground of voltage supply or housing: 60 V DC / 30 V AC ES413.1 - User’s Guide...
3% Digital low-pass filter Butterworth low-pass filter 8th order with selectable cutoff frequency, realized as FIR filter, can be disabled "Automatic": 0.4 * sampling rate "Standard": 0.16 * sampling rate Off": filter is disabled ES413.1 - User’s Guide...
““IN” Connector” on page 67 • ““OUT” Connector” on page 68 • “Sensor Connection Cable” on page 68 All connectors are shown with a view of the front of the ES413.1. All shields are at case potential. 7.9.1 “IN” Connector Fig. 7-2 “IN”...
“Combined Ethernet and Power Supply Cable” on page 72 • “Ethernet Cable” on page 78 • “Protective Caps” on page 81 • “Angle Brackets” on page 83 Only use ETAS cables at the interfaces of the module. Adhere to the maxi- mum cable lengths! ES413.1 - User’s Guide...
Connect the power cable only with a suitable vehicle battery or with a suitable lab power supply! The connection to power outlets is not allowed! To prevent an inadvertent insertion in power outlets, ETAS recommends to equip the combined ethernet and power supply cables with safety banana plugs in areas with power outlets.
(MINI flat automotive fuse, quick-response, 3 A, 58 V). Robust, waterproof and dust-proof (IP67). Temperature rated for: -40 °C to +125 °C / -40 °F to +257 °F Product Length Order number CBEP4105.1-3 F 00K 110 026 ES413.1 - User’s Guide...
(MINI flat automotive fuse, quick-response, 3 A, 58 V). Robust, waterproof and dust-proof (IP67). Temperature rated for: -40 °C to +125 °C / -40 °F to +257 °F Product Length Order number CBEP4155.1-5 F 00K 110 027 ES413.1 - User’s Guide...
(MINI flat automotive fuse, quick-response, 3 A, 58 V). Robust, waterproof and dust-proof (IP67). Temperature rated for: -40 °C to +125 °C/ -40 °F to +257 °F Product Length Order number CBEP4205.1-3 F 00K 110 041 ES413.1 - User’s Guide...
(MINI flat automotive fuse, quick-response, 3 A, 58 V). Robust, waterproof and dust-proof (IP67). Temperature rated for: -40 °C to +125 °C / -40 °F to +257 °F Product Length Order number CBEP4255.1-3 F 00K 110 029 ES413.1 - User’s Guide...
(MINI flat automotive fuse, quick-response, 3 A, 58 V). Robust, waterproof and dust-proof (IP67). Temperature rated for: -40 °C to +125 °C / -40 °F to +257 °F Product Length Order number CBEP4305.1-0m5 0.5 m F 00K 110 030 ES413.1 - User’s Guide...
(MINI flat automotive fuse, quick-response, 3 A, 58 V). Robust, waterproof and dust-proof (IP67). Temperature rated for: -40 °C to +125 °C / -40 °F to +257 °F Product Length Order number CBE401.1-0m5 0.5 m F 00K 106 128 ES413.1 - User’s Guide...
Can also be used to connect ES4xx via PC, ES600 or ES1135 alter- natively while keeping cable installation through bulkhead. Robust, waterproof and dust-proof (IP67). Temperature rated for: -40 °C to +125 °C / -40 °F to +257 °F Product Length Order number CBEX400.1-3 F 00K 105 294 ES413.1 - User’s Guide...
ETAS Protective Caps The connections "IN" and "OUT" of the ES413.1 can be protected with different protective caps according to the operating conditions. 8.3.1 Protective Caps supplied The "IN" and "OUT" ports of the ES4xx are covered with simple dust and trans- port caps on delivery.
ETAS 8.3.4 Cap CAP_SOURIAU_8STA Fig. 8-19 Cap CAP_SOURIAU_8STA The cap CAP_SOURIAU_8STA protects the "Sensor" port against water and dirt. Product Order number CAP_SOURIAU_8STA F 00K 105 303 ES413.1 - User’s Guide...
Angle Bracket for mounting ES4xx modules to a DIN rail 35 x 7.5 (EN 60715 TH35). Stainless steel V2A. For mounting on right side of an ES4xx module. Product Order number Angle bracket right F 00K 107 176 ES413.1 - User’s Guide...
ES413.1 9.1.1 ES413.1-OW Order Name Short Name Order Number ES413.1-OW A/D Module with Sensor ES413.1-OW F 00K 106 863 Supply with Sensor Supply Package Contents ES413.1-OW A/D Module with Sensor Supply with Sensor Supply (open wire), CDROM ES4xx_DRV_SW_CD (drivers for ES4xx and documentation), List "Content...
Cables are not part of the scope of supplies of the module and must be ordered separately (see chapter 9.2.1 on page 85). Accessories 9.2.1 Cables If you require customized cables, please contact your ETAS contact partner or sales.de@etas.com. Cables for the connectors "IN" and "OUT" Ethernet cable Order name...
Order name Short name Order number Cap to protect open Lemo 1B CAP_Lemo_1B F 00K 105 298 sockets against dirt Cap to protect open Lemo 1B CAP_Lemo_1B_LC F 00K 105 683 sockets against dirt, cost effective ES413.1 - User’s Guide...
ES4xx Angle Bracket left ES4xx_AB_L F 00K 107 175 ES4xx Angle Bracket right ES4xx_AB_R F 00K 107 176 9.2.4 Device Calibration Order name Short name Order number Calibration Service for ES413.1 K_ES413 F 00K 106 865 ES413.1 - User’s Guide...
Germany WWW: www.etas.com ETAS Subsidiaries and Technical Support For details of your local sales office as well as your local technical support team and product hotlines, take a look at the ETAS website: ETAS subsidiaries WWW: www.etas.com/en/ contact.php ETAS technical support WWW: www.etas.com/en/...
Need help?
Do you have a question about the ES413.1 and is the answer not in the manual?
Questions and answers