Swp 1250 - Alpha-InnoTec SWP Series Operating Manual

Brine/water heat pumps professional
Hide thumbs Also See for SWP Series:
Table of Contents

Advertisement

Model
Air-to-water heat pump: (yes/no)
Brine-to-water heat pump: (yes/no)
Water-to-water heat pump: (yes/no)
Low-temperature heat pump: (yes/no)
Equipped with supplementary heater: (yes/no)
combination heater with: (yes/no)
application: (low/medium)
climate: (colder/average/warmer)
Item
Rated heat output
Declared coefficient of performance for part load at
indoor temperature 20°C and outdoor temperature Tj
Tj = -7°C
Tj = +2°C
Tj = +7°C
Tj = +12°C
Tj = bivalent temperature
Tj = operation limit temperature
For air-to-water heat pumps: Tj =
+15°C (if TOL < -20°C)
Cycling interval capacity for
heating
Degradation co-efficient (**)
Power consumption in modes other than active mode
Off mode
Thermostat-off mode
Standby mode
Crankcase heater mode
Other items
Capacity control
sound power level,
indoors/outdoors
Emissions of nitrogen oxides
For heat pump combination heater:
Declared load profile
Daily electricity consumption
Contact details
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load
for heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for
heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
44
Subject to change without notice | 83050900dUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Symbol
Value
Unit
Prated
125
kW
Pdh
125,1
kW
Pdh
125,1
kW
Pdh
125,1
kW
Pdh
125,1
kW
Pdh
125,1
kW
125,1
Pdh
kW
Pdh
125,1
kW
Tbiv
-10
°C
Pcych
kW
Cdh
1,0
-
POFF
0,010
kW
PTO
0,010
kW
PSB
0,010
kW
PCK
0
kW
fixed
LWA
79/-
dB
NOX
0
mg/
kWh
-
Qelec
-
kWh
ait deutschland GmbH Industriestr. 3 95359 Kasendorf Germany

SWP 1250

no
yes
no
no
no
no
low
average
Item
Seasonal space heating energy
efficiency
Declared coefficient of performance for part load at
indoor temperature 20°C and outdoor temperature Tj
Tj = -7°C
Tj = +2°C
Tj = +7°C
Tj = +12°C
Tj = bivalent temperature
Tj = operation limit temperature
For air-to-water heat pumps: Tj =
+15°C (if TOL < -20°C)
For air-to-water heat pumps:
Operation limit temperature
Cycling interval efficiency
Heating water operating limit
temperature
Supplementary heater
Rated heat output
Type of energy input
For air-to-water heat pumps:
Rated air flow rate, outdoors
For water-/brine-to-water heat
pumps: Rated brine or water flow
rate, outdoor heat exchanger
Water heating energy efficiency
Daily fuel consumption
Unit
Symbol
Value
ηS
155,0
%
COPd
4,33
-
COPd
4,58
-
COPd
4,84
-
COPd
5,12
-
COPd
4,28
-
4,28
COPd
-
COPd
4,28
-
TOL
-10
°C
COPcyc
-
°C
WTOL
55
Psup
0,0
kW
electrical
m³/h
-
-
22300
m³/h
-
ηwh
-
%
Qfuel
0
kWh

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SWP Series and is the answer not in the manual?

This manual is also suitable for:

Swp1100Swp1250Swp1600Swp700hSwp850hSwp1000h

Table of Contents