set autoping <1 | 2> failcount <1-999>
set autoping mode <single | and | or>
set autoping action <none | on-latch | on-follow | off-
latch | off-follow | cycle>
set autoping cycle <0-999>
set autoping wait <1-999>
set autoping restart <1-999>
set traffic monitor <enable|disable>
set traffic monitor failtime <1-999>
set traffic monitor restarttime <0-999>
set traffic monitor cycles <0-99>
set traffic monitor min
<0-125000000> <kbps|mbps>
set traffic monitor max
<0-125000000> <kbps|mbps>
set traffic monitor maxtest <enable|disable>
set traffic monitor startdisable <hh:mm>
set traffic monitor stopdisable <hh:mm>
get traffic monitor
iboot-poe_v180808n
This command is used to set the number of consecutive failures the AutoPings
must detect before the AutoPing considers the pinged device to be failed.
Sets single AutoPing or two AutoPing relationship And or Or.
This command is used to set the action that the iBoot-PoE will perform when the
autoping triggers.
This command sets the maximum number of power cycles when the AutoPing
triggers. 0 = Unlimited
This command sets the time, in seconds for the device to respond to a ping.
Sets the delay in seconds to restart AutoPing tests after Action. This command sets
the time, in seconds for the device to respond to a ping.
Enable or disable the traffic monitor
Fail time
Restart time
Number of cycles
Min band width
Max band width
Enable/disable maximum bandwidth test
Set the start disable time
Set the stop disable time
Traffic Monitor: Enabled or Disabled
Fail Time: in seconds
Restar Time: in seconds
Number of Cycles:
Minimum Bandwidth: as programmed
Maximum Test: enabled/disabled
Maximum Bandwidth: as programmed
Monitor Disable
Start Time: hh:mm
Stop Time: hh:mm
iBoot-PoE
3
Single
None
1
2
0
Enabled
10
10
0
0
0
Disabled
<00:00>
<00:00>