Automation Inputs (Signals From Efr System To Plc) - Graco CGM 25B127 Instructions - Parts Manual

Communications gateway module. for use with electric fixed ratio (efr) systems to provide fieldbus communications abilities. for professional use only.
Table of Contents

Advertisement

Automation Inputs (signals from EFR system to PLC)

Instance ID
1
Heartbeat To PLC
2
System On
3
System Ready
4
Active Alarms
5
Active Deviations
6
Active Advisories
7
Current Sequence is Playing
8
Current Sequence is Paused
9
Current Sequence is Stopped
10
Dispense Valve Open
11
System is Priming
12
System is Purging
13
System is Parking
14
System is Depressurizing
15
Gel Shot is Running
16
EFR is Dispensing
17
{Reserved Bits}
18
{Reserved Bits}
19
Current Active Sequence
20
Current Step of the Active Sequence
21
Time Remaining to Complete Step (XX.X s)
22
Red Pump Outlet Pressure (XXXX.X bar)
23
Blue Pump Outlet Pressure (XXXX.X bar)
24
Red Pump Inlet Pressure (XXXX.X bar)
25
Blue Pump Inlet Pressure (XXXX.X bar)
26
Pump Flow Rate (XXXX cc/min)
27
Active Error Number Requiring Acknowledgment
Active Operator Mode Dispense Flow Rate
28
(XXXX cc/min)
29
Data Exchanged Element Selected
30
Data Exchanged Element Value
31
Selected Step of the Active Sequence
32
Selected Step Amount (XXXX.XX)
3A6338B
Description
Available Internal Data
Data Type
BIT
Boolean
0
Boolean
1
Boolean
2
Boolean
3
Boolean
4
Boolean
5
Boolean
6
Boolean
7
Boolean
8
Boolean
9
Boolean
10
Boolean
11
Boolean
12
Boolean
13
Boolean
14
Boolean
15
Boolean
16-23
Boolean
24-31
uint8
0-7
uint8
0-7
0-7
uint16
8-15
0-7
uint16
8-15
0-7
uint16
8-15
0-7
uint16
8-15
0-7
uint16
8-15
0-7
uint16
8-15
uint8
0-7
0-7
uint16
8-15
uint8
0-7
0-7
uint16
8-15
uint8
0-7
0-7
8-15
uint32
16-23
24-31
Input Byte
Index's
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cgm 26a701Cgm 26a700Cgm 26a702