Customer Inputs/Outputs - Graco PD44 Setup & Operation

Control box
Table of Contents

Advertisement

Customer Inputs/Outputs

Customer Inputs/Outputs
Name
Ready to Dispense Signal (Output)
Cycle-Complete (Output)
Customer Start (Input)
F
. 13
IG
26
Description
In Shot Mode, changes state when pump is retracted and LS-EXT is tripped.
In Shot Mode, changes state for one second after the retract switch is
tripped.
In any mode, operates in parallel to the footswitch. Provide a dry contact
closure between black and white wires on the customer signal cable to
actuate machine.