Desired Number of Times to Run the
Sequence
Desired Number of Times to Run the Sequence is an
integer used to define the number of times the
sequence will run.
Example: If the integer is 5, the sequence will run 5
times before the dispense is finished.
Actual Number of Times the Sequence has
Ran
Actual Number of Times the Sequence has Ran is an
integer used to define the number of times the
sequence has run out of the desired number.
Example: If the integer is 10, the sequence has run 10
of X times. X represents the Desired Number of Times
to Run the Sequence.
NOTE: This integer can only be read by the PLC.
Mixed Material Specific Gravity
Mixed Material Specific Gravity is an integer used to
define the specific gravity of the mixed material.
NOTE: This integer can only be read by the PLC.
Sequence Start Outlet Pressure for Red
Pump
Sequence Start Outlet Pressure for Red Pump is an
integer that represents the outlet pressure of the red
pump once the active sequence begins dispensing.
NOTE: This integer will only be populated after the
active sequence is done dispensing.
NOTE: This integer can only be read by the PLC.
Sequence Start Outlet Pressure for Blue
Pump
Sequence Start Outlet Pressure for Blue Pump is an
integer that represents the outlet pressure of the blue
pump once the active sequence begins dispensing.
NOTE: This integer will only be populated after the
active sequence is done dispensing.
NOTE: This integer can only be read by the PLC.
3A6338B
Sequence End Outlet Pressure for Red
Pump
Sequence End Outlet Pressure for Red Pump is an
integer that represents the outlet pressure of the red
pump once the active sequence is done dispensing.
NOTE: This integer will only be populated after the
active sequence is done dispensing.
NOTE: This integer can only be read by the PLC.
Sequence End Outlet Pressure for Blue
Pump
Sequence End Outlet Pressure for Blue Pump is an
integer that represents the outlet pressure of the blue
pump once the active sequence is done dispensing.
NOTE: This integer will only be populated after the
active sequence is done dispensing.
NOTE: This integer can only be read by the PLC.
Sequence Inlet Pressure for Red Pump
Sequence Inlet Pressure for Red Pump is an integer
that represents the inlet pressure of the red pump for the
current sequence being dispensed.
NOTE: This integer will only be populated after the
active sequence is done dispensing.
NOTE: This integer can only be read by the PLC.
Sequence Inlet Pressure for Blue Pump
Sequence Inlet Pressure for Blue Pump is an integer
that represents the inlet pressure of the blue pump for
the current sequence being dispensed.
NOTE: This integer will only be populated after the
active sequence is done dispensing.
NOTE: This integer can only be read by the PLC.