Gel Timer Sequence Selected
Gel Timer Sequence Selected is an integer used to
define the sequence that will run when the gel timer
expires.
NOTE: To use the active sequence as the selected
sequence for the gel timer, a new value of zero must be
sent across the data exchange. If a new value of zero is
not sent, the number sent across the data exchange will
correspond to the sequence selected for the gel timer.
Smart Prime Repeat Unit
Smart Prime Repeat Unit is an integer used to define
the amount of material dispensed for the smart prime.
Smart Prime Sequence Selected
Smart Prime Sequence Selected is an integer used to
define the sequence that will run when smart prime is
enabled.
NOTE: To use the active sequence as the selected
sequence for smart prime, a new value of zero must be
sent across the data exchange. If a new value of zero is
not sent, the number sent across the data exchange will
correspond to the sequence selected for the gel timer.
Purge Flow Rate
Purge Flow Rate is an integer used to define the flow
rate at which the Purge Request will dispense.
Over Pressure Alarm
Over Pressure Alarm is an integer used to define the
maximum pressure that can be reached before the EFR
shuts down and returns the error.
Integration External Trigger Enabled
Integration External Trigger Enabled is a boolean that
can enable usage of the Integration Trigger I/O pin. The
following values correspond to the different states of the
Integration External Trigger Enabled boolean.
Integration Trigger
Value
0
1
3A6338B
Enabled State
Not Enabled
Enabled
Integration External Trigger Status
Integration External Trigger Status is a boolean that
shows the status of the Integration Trigger I/O pin. The
following values correspond to the different states of the
Integration External Trigger Status boolean.
Integration Trigger
Value
0
1
Integration Smart Prime Enabled
Integration Smart Prime Enabled is a boolean that can
enable usage of the Integration Smart Prime I/O pin.
The following values correspond to the different states
of the Smart Prime Enabled boolean.
Integration Smart Prime
Value
0
1
Integration Smart Prime Status
Integration Smart Prime Status is a boolean that shows
the status of the Integration Smart Prime I/O pin. The
following values correspond to the different states of the
Smart Prime Status boolean.
Integration Smart Prime
Value
0
1
Integration System Enabled
Integration System Enabled is a boolean that can
enable usage of the Integration System I/O pin. The
following values correspond to the different states of the
Integration System Enabled boolean.
Integration System
Value
0
1
Appendix B - Data Exchanged
Status State
Not Active
Active
Enabled State
Not Enabled
Enabled
Status State
Not Active
Active
Enabled State
Not Enabled
Enabled