Pyronix PCX 78 Installation Manual page 78

Table of Contents

Advertisement

Fault
MAINS FAIL xxx
FUSE x FAULT
LOW VOLTS xxx
Table 28 - Engineer Indications
Fault
Engineer Access
Denied
Check Failed Input xxx
Error Area not
accessible
Error some Areas
cannot be disarmed
Table 29 - Wireless Faults
These faults will only be possible if you have a wireless expansion module installed.
Fault
U-01 (xx) WLs LOW
BATT
I-01 (xx) WLs LOW
BATT
B-01 (xx) WLs LOW
BATT
I-01 (xx) WLs
SUPERVN
B-01 (xx) WLs
SUPERVN
- 01 (xx) TAMPER ON
INPUT
WLs TAMPER Bxx
78
PCX Installation Guide
Description
Mains supply failed
Fuse identified failed, OR Output protected by
fuse drawing excessive current
Power supply volts low
Description
Access to Engineer Menu NOT possible, as
system is not fully disarmed.
Input in fault on attempting to exit Engineer
mode.
A Input has been programmed to an area for
which no arming point is valid to disarm.
Arming points have been programmed so it's
possible to arm an area, but not disarm it.
Description
Low battery on wireless keyfob (user) number xx
Low battery on wireless Input number xx
Low battery on wireless bell number xx
Device on wireless Input number xx has not
'checked in'
Wireless bell number xx has not 'checked in'
within time of 20 min
Tamper fault on input number 01 xx = any input
number
Tamper fault on wireless bell number xx
Solution
System detects mains frequency out of
specification, as well as voltage.
The AC FAIL timer is operative.
Fuse 1 = Bell
Fuse 2 = Aux
Fuse 3 = BUS
Fuse 4 = Battery
Ensure the voltage coming out of the control
panel PSU is ~12VDC.
Solution
Ensure that ALL areas are disarmed, using a
suitable User Codes / tags at appropriate
keypads / readers.
Applies to 24-hour tamper, or other Input types
that would generate an alarm condition if the
system were returned to disarmed mode. Also
applies to tamper fault on other Input types.
Check for fault on Input, or omit in programming.
It would therefore be impossible to fully disarm
the system after a tamper alarm on that Input.
Programming must be adjusted before exiting
Engineer mode.
Programming must be adjusted before exiting
Engineer mode.
Solution
Replace the battery on the mentioned keyfob
Replace the battery on the mentioned Input
device
Replace the battery on the mentioned radio bell
Walk test the detector, perform a diagnostic –
signal strength test and try replacing the battery
Test the bell, perform wireless signal strength
diagnostic. Consider replacing the battery or
relocating the bell.
Check the tamper switch on the detector and
make sure the case is closed properly.
Check the tamper switch on the mentioned radio
bell
102017852 - V01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents