Pyronix PCX 78 Installation Manual page 83

Table of Contents

Advertisement

No.
Output
Type
0004
Final Arm All
0005
Open After
Alarm (Abort)
0007
Tamper Any
0008
Duress Any
0009
PA Device Any
0010
Gas
0011
Arm Fail
0012
Entry
Deviation
0013
System Ready
Any
0014
Bell Any
0016
Strobe Any
0017
Bypass Rearm
Any
0018
Burglary
(Unconfirmed)
Any
0019
Ready All
0020
Exit Starts All
0021
Exit Starts
Any
0022
Final Arm Any
0023
Strobe if Arm
Fail
0024
Unable to
Arm
0025
Keyswitch
Disarm
0026
Arm with
Bypass
0027
Pulsed
Burglary Any
0028
Power Fault
0031
Entry
0032
Exit
0033
Entry / Exit
0034
Lights
PCX Installation Guide
Active
When ALL areas are armed
When system is silenced after 'burglary' alarm
has been activated
Tamper alarm in any area
At a Duress alarm in any area
At alarm on a PA input only from any area. (This
does not include the keypad PA)
At gas alarm
Pre-set time after start of exit time, if exit
procedure is not complete
When deviation from entry route occurs, during
entry time
When any of the inputs but the Entry Delay and
Follow are closed
After alarm in any area
After alarm in any area
When inputs are bypassed at rearm in any area
At Burglary alarm in any area
When all inputs but the 'Entry Delay' and 'Follow'
inputs are closed
At start of exit time to arm LAST area
When exit time starts to arm FIRST area
When ANY area has been armed
Works similar to output 016, but also fires if the 'arm fail' timer expires
This output turns on for 5 seconds when the system is disarmed via a keyswitch input (either pulsed
or latched keyswitch)*
Output activates when an arming procedure is completed with inputs bypassed
Active when the system is armed with an input bypassed
Active when burglary alarm is triggered, but deactivates once the Pulsed Intruder timer has expired
Active during low volts and battery faults. Restores at code entry after fault cleared
Active during any Entry time
Active during any Exit time
Active during any entry or exit time
When exit or entry timer starts
102017852 - V01
Restore
At code entry to disarm
After 2 minutes
At code entry to silence
When a valid code is entered
When a valid code is entered
When a valid code is entered
At code entry to rearm
At code entry to disarm
If fault exists, and after final arm
When alarm silenced or when siren timer expires
When disarmed or when strobe timer expires
When system disarmed
At code entry to silence
If fault exists, and after final arm
At disarm FIRST area (i.e. no longer fully armed)
At code entry to disarm LAST area
At code entry to disarm LAST area
20 seconds after arm/disarm procedure
completed
83