No.
Output
Type
0035
Follow Input
0037
Restore 1
0038
Restore 2
0039
PIR Latch 1
0040
PIR Latch 2
0041
AC Mains
Good
0042
PIR LED
Enable
0043
Follow Test
0044
Off During
Test
0048
Walk Test
0049
Detector
Masked
0050
Follow 24
Hour
0051
Line/GPRS
Fault
0052
AC Mains Fail
0053
Battery Fault
0054
Low Volts
0055
Global Fault 1
(Grade 2)
0056
Global Fault 2
(Grade 3)
0057
German Relay
0058
Guard Code
Used
0059
Engineer
Access
0060
Follow Power
Up
0063
Test UK STU
84
PCX Installation Guide
Active
Active when a specific input number has been activated. It allows the following options to be
programmed:
-
Follow Type (Follow, Timed, Latched, Code Reset);
-
Follow What (Input, Sub-Area, Area);
-
Follow When (Always, When Armed, When Disarmed);
-
Input to Follow (between 1 to 64)
At code entry to arm. The normal state of this
input is 0v and it changes to 12v when activated.
Activates whenever an additional area is armed.
The normal state of this input is 0v and it
changes to 12v when activated.
When armed (and in Walk Test)
This is the inverse polarity to PIR Latch 1
Output showing the 230v mains supply is present
This output activates during walk test
Output will activate only when tested from the Engineer Menu 'Test Outputs' in the 'Engineer Tests'.
This output can be used as additional facility for testing the operation of a Bell. An output
programmed to one of these configurations (43 and 44) may be used to trigger a relay to break the
hold-off connection to the Bell – or even to provide the hold-off directly.
Output is normally active and will deactivate only when tested from the Engineer Menu 'Test Outputs'
in the 'Engineer Tests'.
Same as 43 but opposite activation.
This output is active during walk test, and will only deactivate when all detectors have been tested
If any detector goes into 'mask' condition the
output will activate
If any input programmed as '24 Hour' activates
When Telephone or GPRS Line Fault is present
After pre-set time without mains power
When battery disconnected or load fail detected
When less than 11.2v are present
Activates if any fault occurs only when system is
armed
Activates if any fault occurs at any time
For future development. Do Not Use.
When 'guard' code used on the system
When entering Engineer Mode
At power up
Activates when a test call is sent
Restore
After 3 seconds
When disarmed
At alarm, or when disarmed
At alarm, or when disarmed
When masking fault clears
When input is restored
When fault clears
On restoration of mains
At next valid code entry
When fault clears
When all faults cleared
When all faults cleared
After 60 seconds
When leaving Engineer Mode
Live for 45 seconds
When test completed
102017852 - V01