Access Control Sequences (6R5) - Mitel SmarT-1 EuroRoute Installation & Programming Manual

Dialer
Table of Contents

Advertisement

Access Control Sequences

9. 3. Access Control Sequences (6R5)

Access Control Sequences (ACS) instruct the EuroRoute on how to access a particular carrier-
telephone network. Calls are routed in the ACS after a match in the Search Tables is detected.
Each entry (6R5) can be any sequence of commands taken from the following tables, with a
maximum of 80 characters per entry.
Register
Token
6R5
00
01
02
Where R
03
Equals
04
1 - 8 for
05
Routes
06
1 - 8
07
08
See
09
Section
0
9.2.
10
11
12
13
14
18
19
21
22
23
24
25
26
27
28
29
30
31
34
35
36
† This ACS Token may only be used when installing the EuroRoute on Loop Lines.
†† This ACS Token will only be active if all of the destination number digits have been
dialled.
65
Dials the digit 0
Dials the digit 1
Dials the digit 2
Dials the digit 3
Dials the digit 4
Dials the digit 5
Dials the digit 6
Dials the digit 7
Dials the digit 8
Dials the digit 9
Dials the digit
Dials the digit #
Dials the Destination Number (Buffer A)
Dials the Cost Centre Code (Buffer B)
Dials Contents of Buffer C
(Second Cost Centre Code Buffer)
Drop and Reseize Exchange Line †
Wait for Cost Centre Code (Do Not Dial)
Dial the Contents of Register S31 (PABX/Centrex Digit)
Dials Contents of Register 6R1
Dials Contents of Register 6R2
Dials Contents of Register 6R3
Dials Contents of Register 6R4
Dials Contents of Register 605
Dials Contents of Register 606
Dials Contents of Register 607
Dials Contents of Register 608
Dials Contents of Register 609
Set Exchange side monitor off
Set Exchange side monitor on ††
Dials Trunk Number that the user is on
Cut through - End of ACS Execution
Switch to MF4 Dialling
Description
8350-383-113-BA
Draft 1A, September 1998

Hide quick links: