Step
8
The outdoor unit has 2
discharge grilles.
Remove the 4 screws
and unfasten the 4
hooks to remove a
discharge grille.
9
Remove the 7 screws
of the front panel (1).
10
Push the front panel (1)
upward and remove it.
Removal Procedure
Procedure
Discharge
grille
Discharge
grille
Hook
Front
panel (1)
Hook
Hook
(R18960)
Reinforce plate
(R18961)
Outdoor Unit
Points
U.S. model:
The front panel (1) has 2 air
outlet protection nets. To
detach an air outlet
protection net, remove the 4
screws.
On the rear side of the front
panel (1), a reinforce plate is
attached. Be careful not to
lose it while removing the
front panel (1).