Daikin RMKS112LV1A Service Manual page 10

11.2/14.0/16.0 kw class 48000 btu/h class
Table of Contents

Advertisement

Outdoor Unit
Step
9
Remove the 2 screws
of the insulation sheet
and then release the
compressor lead wires
(blue, red, white) and
the relay wires between
A1P and A3P (red,
blue) from the hooks.
10 Remove the 2 screws
from [LB] (red) and [NB]
(blue) on A3P and
disconnect the 2 lead
wires of condenser
(orange, gray).
8
Procedure
Orange
Gray
Condenser (C4)
(R9229)
(R9230)
[NB]
[LB]
(R12968)
Si181296_A
Points
M4 × 8 with spring washer
Removal Procedure

Advertisement

Table of Contents