Daikin RMKS112LV1A Service Manual page 11

11.2/14.0/16.0 kw class 48000 btu/h class
Table of Contents

Advertisement

Si181296_A
Step
11
Cut the 2 clamps for the
compressor lead wires.
12
Cut the clamp for the
relay wires from A3P to
A1P (red, blue) and for
the earth / ground
(green).
Clamps (2 places) for the
compressor lead wires
13 Push and unfasten the
2 hooks and slide the
casing to the right and
remove the casing from
the electrical
component assembly.
Removal Procedure
Procedure
Points
Clamp for the relay wires from A3P to
A1P and for the earth / ground
(R18980)
(R9233)
Hook
(R9234)
(R9235)
Outdoor Unit
9

Advertisement

Table of Contents
loading