Step
16 Remove the screw at
the top of the electrical
component assembly.
17 Unfasten the 2 hooks at
the rear side.
18 The figures in the right
are PCB assembly.
Removal Procedure
Procedure
Electrical component
mounting plate
(R9238)
(R12972)
Service PCB
(A2P)
Main PCB (A1P)
Cool / heat selector
(for control)
PCB (A4P)
(R12973)
Outdoor Unit
Points
M4(2) × 12
Fixing plate for the
PCB
Hook
Electrical component
mounting plate
Noise filter PCB
(A3P)