Teaching-In - HomeMatic HM-LC-Sw1-PB-FM Installation And Operating Manual

Switch/blind actuators.flush mount, with pushbutton:
Table of Contents

Advertisement

Available languages

Available languages

7.2 Teaching-in

Please read this entire section before starting the
teach-in procedure.
To execute the teach-in procedure, both of the
devices to be connected must be in teach-in mode
and the channel to be taught-in must be selected.
The actuators have one or two teach-in buttons.
- To teach-in to a specific actuator channel, press
and hold down the corresponding teach-in button
for approximately four seconds.
The device LED will flash red continuously to
indicate that teach-in mode is active.
- To exit teach-in mode prematurely, press the
teach-in button again briefly. The device LED will
go out.
If no teach-in is carried out, teach-in mode will be
exited automatically after 20 seconds.
If other devices are also in teach-in mode, they will
be taught-in.