Installation - HomeMatic HM-LC-Sw1-PB-FM Installation And Operating Manual

Switch/blind actuators.flush mount, with pushbutton:
Table of Contents

Advertisement

Available languages

Available languages

6

Installation

The actuators for flush mounting are suitable for
mounting in installation boxes.
If a number of flush-mounted actuators are to
be mounted in installation boxes located next
to or above one another (connected or not
connected), the total switched current must
not exceed 16 A.
The connection of the actuators described is
illustrated in the following connection diagrams.
Only cables rated for mains voltage may be used.
Only loads for which the actuator has been
approved should be connected to the outputs.
- Wire the actuator (strip the cables ends back
9 mm) and position it inside the installation box
with the terminal strip pointing downwards.
- Screw the actuator to the installation box.
- Connect the mains voltage and test the function of
the actuator by repeatedly pressing and releasing
the teach-in/test button.
37

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Hm-lc-sw2-pb-fmHm-lc-bl1-pb-fm

Table of Contents