Switch actuator:
It is absolutely essential to take the technical data
(in particular the maximum permissible switching
capacity of the relay and the type of load to be
connected) into account before connecting a load.
All load data relates to ohmic loads.
Blind and shutter actuator:
The actuator is only suitable for 230 V AC motors.
It is not suitable for connection to three-phase
motors and DC motors.
If motors are to be connected in parallel at the
actuator's output, compliance with the motor
manufacturer's data is absolutely essential.
Noncompliance could result in the motors being
damaged beyond repair.
Only shutters and blinds with limit switches
(mechanical or electronic) should be used.
Before putting the blind and shutter actuator into
operation, check that the limit switches on the
connected motors have been adjusted correctly.