13 Technical data

Radio frequency:
Typ. open air range:
Power supply:
Current consumption:
Standby consumption:
Degree of protection:
Protection class:
Housing:
Housing colour:
Dimensions:
HM-LC-Sw1-PB-FM
Relay:
Switching capacity:
HM-LC-Sw2-PB-FM
Relay:
Switching capacity:
HM-LC-Bl1-PB-FM
Relay:
Switching capacity:
48
868.3 MHz
100 m
230 V/50 Hz
10 mA
0.5 W
IP20
II
ABS
Green
70 x 70 x 34 mm
(H x W x D)
NO contact
5 A (ohmic load)
2 x NO contacts
5 A (total for both
channels, ohmic load)
1 x NO contact and
1 x CO contact
1 A/250 W motor load