A. Technical appendix
A.6
Technical specifications of the pneumatic interfaces
Technical data
General technical specifications of the
CPX terminal
Protection class as per EN 60 529
Operating voltage supply for
electronics/sensors (V
– Nominal voltage
– Intrinsic current consumption at 24 V
(internal electronics)
Load voltage supply for valves (V
– Nominal voltage
– Intrinsic current consumption at 24 V
(internal electronics, without valves)
– Diagnostic message undervoltage
V
(monitoring V
VAL
VAL
outside function range)
Digital outputs (valve solenoid coils)
– Rated load voltage
– Intended for connecting to
pneumatics
– Short circuit protection at valve
output
– Monitoring wire fracture (open load)
Isolation
Galvanic isolation
– between the channels
(valve solenoid coils)
– between the operating voltage
supply for the electronics/sensors
(V
) and the load voltage for the
EL/SEN
valves (V
)
VAL
Module code [type code] (CPX-specific)
Module identification (Handheld)
A-12
VABA-S6-1-X1/-X2 for VTSA pneumatics (ISO)
See CPX System Description
IP65, in fitted state
)
EL/SEN
DC 24 V ± 25 %
Typ. 15 mA
)
VAL
DC 24 V ± 10 %
Typ. 30 mA
≤ 21.6 ... 21.5 V
, load voltage
Max. 32 outputs
V
VAL
VTSA (ISO, type 44)
Yes (electronic),
Response threshold > 1.0 A
Capable of parameterisation
Tested with 500 V DC
None
With power supply via interlinking block type:
– CPX-GE-EV-S: None
– CPX-GE-EV-S-7/8-5POL: Yes
– CPX-GE-EV-V...: Yes
69
ISO Plug-In or type 44 (depending on the version of the
Handheld)
Festo P.BE-CPX-EA-EN en 1105h