5. CPX pneumatic interfaces
Module parameters:
Monitoring wire fracture channel x (only CPA and VTSA pneumatics)
Function no.
- channel 0 ... 7:
4828 + m * 64 + 6
- channel 8 ... 15:
4828 + m * 64 + 7
- channel 16 ... 23:
4828 + m * 64 + 8
- channel 24 ... 31:
4828 + m * 64 + 9
Description
Determines whether Monitoring Wire Fracture for the relevant channel is active
or inactive (CPA: Channel 0 ... 21, VTSA/ISO: Channel 0 ... 31).
Monitoring wire fracture output channel ...
0 = inactive (presetting)
1 = active
Note
With Monitoring Wire Fracture, a missing valve or a wire fracture (connection
fault between the pneumatic interface and the valve coil) is recognised.
[...] = display in the Handheld
Tab. 5/5:
Monitoring wire fracture channel x (channel-specific)
Module parameter: Fail safe channel x
Function no.
Access to these module parameters is enabled via protocol-specific functions
(see the manual for the bus node).
Description
Fault mode channel x:
Fault state channel x:
Note
With the aid of so-called Fail Safe parameterisation, you can specify which signal
status the outputs are to assume in the event of fieldbus communication errors
(also see CPX system manual).
Tab. 5/6:
Fail Safe channel x (channel-specific)
5-18
m = module number (0 ... 47)
Hold last state
Fault state (presetting)
Set output
Reset output (presetting)
[Monitor open circuit Out Ch ...]
[Inactive]
[Active]
Festo P.BE-CPX-EA-EN en 1105h