5.5 FORMAT OF THE COMMANDS
The following commands operate with the serial interfaces COM1 and USB of the datalogger.
The commands are 4 to 12 bytes long:
Begin of command:
0x02(Hex) / Ctrl-B
LIST OF THE COMMANDS:
"HH"
"PD"
"RS"
„CC1"<0..9>
"CC2"<0..9>
"CC3"<0..9>
„CR"<n><0,1>
"Cs000 "aaa' 'bbb
„MT"<01s,02s,03s,04s,05s,06s,10
s,12s,15s,20s,30s,01m,02m,03m,
04m,05m,06m,10m,12m,15m,20
m,30m,60m>
„ST"<01m,02m,03m,04m,05m,06
m,10m,12m,15m,20m,30m,60m>
„ET"<01m,02m,03m,04m,05m,06
m,10m,12m,15m,20m,30m,01h,0
2h,03h,04h,06h>
„SS"
„GS"
"EE"
"TS"<DdMoYy>
"ts"<d><m><y>
„DS"<DdMoYyHhMi>
"ds"<d><m><y><h><m>
"TE"<DdMoYy>
"te"<d><m><y>
STX ? ? ? ? ? ? ? ? ? ? ETX
Command:
2 ... 10 Bytes
Help: indicates the list of entering commands
Turn Datalogger into "power down" (display off, Measuring-Mode)
Reset of the Datalogger. Start of Bootloader
Set baud rate COM1
Set baud rate COM2
Set baud rate COM3
Set operation mode COM n(n = 1,2)
Configure sensor or telegram for COM2 and COM3
aaa:COM2 bbb:COM3 values according to index in Table 5
Example: STX "Cs000 008 001"ETX
COM2: 8 (-> SIF002) COM3: 1 (-> SONIC)
Ref. to chap.3.2.5 for additional remarks. Old data can be deleted!
Set measuring cycle in seconds or minutes
Set mean storing cycle in minutes
Set extreme storing cycle in minutes and hours
Output of all stored mean values
Complete mean memory:
Reasonable only, when the logger has re-initialised itself, in order to
save data which have not been overwritten
Output of all stored extreme values
Stored mean data of one day
Description of parameters: ref. to chap. 5.5.1
Output of stored mean data from a specific time
Description of parameters: ref. to chap. 5.5.1
Stored extreme data of one day
Description of parameters: ref. to chap. 5.5.1
43 - 56
End of command:
0x03(Hex) / Ctrl-C
0:300Bd ... 5:9600Bd ... 9:115200Bd
0:RS232 1:RS485-4w
021579/06/09
Need help?
Do you have a question about the DLx-MET and is the answer not in the manual?