THIS DRA W I NG IS T H E E X CLUSI V E PROPERT Y
OF MAGNETRO L I NTERNAT I ONA L. NO USE
W HATSOEVER O F T H E I NFORMAT I ON CON -
THI RD ANG LE
PROJ ECTI ON
TAI NED HEREON, NOR REPROD
UCTI ON I N
W HOLE OR I N PART MA Y BE MADE W I THOUT
I N
THE E X PRE SS W RI TTEN PERM I SSI ON OF:
( mm )
MAGNETRO L I NTERNAT I ONA L
HAZARDO US LOCATI ON
I NTRI NSI CALL Y SAFE CONNECTI ON S CLASS I , II , III D I V 1
UPS B, C,D,E,
GRO
4 T a = 71°C
T
NON - I NCENDI VE
CLASS I
DI V 2 GROUPS A, B, C,D
CLASS II DI V 2 GROUPS E, F,G
( F & G ON L Y FOR FM )
SMART E S II / E Z MODULEVE L
TRANSM I TTER
I NSTRUMENT
SEALED N I PPLE
( EPOXY FILL ED)
W I THOUT METER
W I TH METER
( W I NDO W ED)
MODE LS APPROVED
x E x x - xxxx - R SQ, R ST, R SZ FOR SMART E S II
ZQ, R ZT, FOR E Z MODULEVE L
R
M
NOTE:
1. AN Y CHANGES TO T HIS DRA W I NG MUST BE SUBM I TTED TO FACTORY MUTUAL & CSA
PER
SPI SE0- 006.
2. MANUFACTURE' S I NSTRUCTI ON S SUPPLI ED W I TH T HE PROTE CTI VE BARRI ER, CEC ( CSA)
OR T
HE NE C MUST BE FOLL OW ED W HEN I NSTALLI N G T HIS E QUI PMENT.
3. FOR I NSTALL ATI ON GUI DAN CE, SEE AN S I / IS A RP1 2 . 6.
4. FOR CSA: E XI A I NTRI NSI CALL Y SAFE/ SECURI TE I NTRI NSEQUE.
5. FOR CSA: W ARNI NG - EXPLOSI ON HAZARD- SUBSTI TUTI ON OF COMPONENT S MAY
I MPA I R SUI TABILI TY FOR HAZARDO US LOCATI ON S.
FOR CSA: W ARNI NG - EXPLOSI ON HAZARD- DO NOT D IS CONNECT E Q UI PMENT
UNLESS PO W ER HAS BEEN SW I TCHED O FF OR T HE AREA IS KNO W N TO BE
NON -H AZARDO US.
6. FOR SUPPLY CONNECTI ON S USE W I RE SUI TABLE FOR T HE OPERAT I NG
TEMPERAT
URE. FOR 71°C AMBI ENT USE W I RE W I TH A M I NI M UM
TEMPERAT
URE RAT I NG OF 75°C.
7. T HE TRAN S M I TTER MA Y A LS O BE I NSTALL ED I N CLASS I , D I V. 2,
GRO
UPS A, B, C, & D ; CLASS II , D I V. 2, GRO UPS E, F, & G ( F & G ON L Y
FOR FMR C) ; CLASS III
, D I V. 2, LOCATI ON S AND DOE S NOT RE QUI RE
CONNECTI ON TO A PROTE
CTI VE BARRI ER W HEN I NSTALL ED PER CEC
( FOR CSA) OR NE C ( FOR FMR C) AND W HEN CONNECTED TO A PO
W ER
SOURCE NOT E XCEEDI NG 30 VD C.
Figure 11
THI S DRAW I NG I S THE EXCLUSI VE P ROPERTY
OF M AGNETROL I NTERNATI ONAL. N O USE
THI RD ANGLE
W HATSOEVER OF THE I NFORM ATI ON CON-
PROJ ECTI ON
TAI NED HEREON, N OR REPRODUCTI ON I N
W HOLE OR I N P ART M AY BE M ADE W IT HOUT
I N
THE EXPRESS W RITTE N P ERM I SSI ON OF:
M AGNET ROL I NTE RNATI ONAL
( mm )
HAZARDOUS LOCATI ONS
SM ART ES II / EZ M ODULEVEL
x M ODEL Exx - xxxx - ESD, ESI , ESJ , ESH, ESK, ES8 OR ES9 FOR SM ART ES II
EZD, EZI , EZH, OR EZK FOR EZ M ODULEVEL
I ntr i n s i call y Safe for CL I , Di v. 1 Groups A B C D
CL II , Di v. 1 Groups E F G
CL III N EM A 4X ( FM ) TYPE 4X ( CSA)
T4 Ta = 71°C
TRANSM ITTE R
I NSTRUM ENT
SEALED N I PPLE
( EPOXY FI LL ED)
W IT HOUT M ETE R
W IT H M ETE R
( W I NDOW ED)
NOTE S:
1) Barr i ers m ust be CSA Cert i f i ed and FM approved .
2) M anuf acturers in st all at i on in stru ct i ons supp l i ed w i t h t he prote ct i ve barr i er and
t he CEC ( for CSA) or t he N EC and ANSI / I SA RP 1 2 .6 ( For FM RC) m ust be fo ll ow ed
when in st all in g t he equi pm ent .
3) Contro l equi pm ent connected to prote ct i ve barr i ers m ust not use or gener ate m ore
t han 250 Vdc or Vr m s .
4) N RTL l i sted dust t i ght se al s m ust be used when dev i ce i s in st all ed in
Cl ass II & III envi ro nm ents .
5) N o rev i s i ons to t hi s dr aw in g w i t hout FM RC and CSA approv a l .
6) For CSA: Exi a I ntr i n s i call y Safe / Se cur i te I ntr i n se que
7) For CSA: W ar nin g Expl os i on Hazard Subst i tut i on of com ponents ma y i m pai r
su i t abi l i t y for hazardous Locat i ons .
For CSA: W ar nin g Expl os i on Hazard Do not di s connect equi pm ent unl ess
pow er has bee n s w i t ched off or t he are a i s know n to be non- hazardous .
8) For supp l y connect i ons , use w i re su i t abl e for oper at in g te m per ature .
For 71°C am bi ent , use w i re w i t h a m ini m um te m per ature r at in g of 75°C.
9) The tr a ns m i tter ma y al so be in st all ed in Cl ass I Di v 2 groups A, B, C, D,
Cl ass II , Di v 2 Groups E, F & G ( F&G onl y for FM RC) ; Cl ass III
, Di v 2
l ocat i ons and does not re qui re connect i on to a prote ct i ve barr i er when
in st all ed per CEC ( for CSA) or N EC ( for FM RC) and when connected to a
pow er sour c e not exceed in g 30 V DC.
Figure 12
9
SAFE LOCATI ON
F & G
THE VO LTAGE ( Vmax) AND CURRENT ( I max)
W HI CH T H E TRAN S M I TTER CAN RE CEI VE
M UST BE E Q UAL TO OR GREATER T
THE MA XI M UM OPEN CI RCUI T VO LTAGE
( Voc OR V t ) AND T HE MA XI M UM SHORT CI RCUI T
CURRENT ( I sc OR I t ) W HI CH CAN BE DE L I V ERED
BY T H E SOURCE DEV I CE. I N ADDI TI ON, T HE
MA XI M UM CAPACI TANCE ( Ci ) AND I ND UCTANCE
( Li ) O F T H E LOAD AND T H E CAPACI TANCE
AND I ND UCTANCE O F T H E I NTERCONNECTI NG
W I RI NG, M UST BE E Q UAL TO OR LESS T H AN
THE CAPACI TANCE ( Ca) OR T HE I ND UCTANCE
( La) W HI CH CAN BE DR I VEN BY T H E SOURCE
COND UI T J UNCTI ON
DEVI CE.
FI TT I NG
ENT I TY
Vmax = 28. 6V
I max = 1 40m A
Ci = 5nF
Li = 434µH
Pmax = 1 W
M
M
ALTERNAT I VELY - FM ONLY
Vmax = 22V
I max = 1 65 m A
Ci = 5nF
Li = 43µH
Pmax = 1 W
8. REMOTE MO UNT LVDT & E L ECTRONI CS HOUSI NG
UST BE I NSTALL ED E X PLOSI ON PROOF.
M
9. NRT L LIS T ED D UST T I GHT SEALS MUST BE
USED W HEN I NSTALL ED I N CLASS II & III
I RONMENT S.
ENV
MATERI AL
RAW MAT L PART NO .
HEAT TREAT
FI NIS H
Intrinsically Safe Wiring
CONDUIT J UNCTI ON
FITTI NG
ENTITY
Vmax = 28.6V
I max = 1 40m A
Ci = 5 nF
Li = 434µH
Pmax = 1 W
ALTE RNATI VELY - FM ONLY
Vmax = 22V
I max = 1 65m A
M
Ci = 5 nF
Li = 434µH
Pmax = 1 W
M ATE RI AL
RAW M ATL P ART N O.
HEAT TREAT
FI NI SH
Intrinsically Safe Connections/Non-incendive wiring
SYM
DESCRI PTI ON
H
PG. 1: REDRA
W N ON CAD.
ADDED: PG . 2, P / N - 002.
J PG 1: ADDED: NOTE 8, RMVD:
EXPLOSI ON PROOF & D UST
I GNI TI ON PROOF FROM HAZARD-
OUS LOCATI ON, CHGD: G W AS 6;
PG 2 CHGD TO PG 3, ADDED NE W
PG 2; PG 3 ADDED: SMART E SII
MOD ULEVE L & E S 9 TO HAZARDOUS
LOCATI ON S & RMVD G S H, G SK,
GSQ, G ST, G S4, R SQ, R ST, R SZ;
ADDED: ILLUS T RAT I ON & NOTE 9,
CHGD NON HAZARDOUS LOCATI ON:
Vt & I t W ERE V + & I e RE S P.
K
PG. 1 & 2: ADDED E S II TO
TI TLE, T 4 T a =71°C & E Z TO
HAN
TO SMART E S II MODULEVE L
CALL OUT. ENT I TY CI W AS 5pF.
REVIS ED MODELS APPROVED .
DRW G. W AS 3 PAGE S .
L
PAGE 1 - CHG' D: LI M I TI NG
VALUES 5nF W AS 5pF, 434µH
W AS 434nF. BOTH PAGE S -
CHG' D: ENT I TY 434µH W AS
434nH. PAGE 2 - ADDED TO
NOTE 7 SECOND CSA W ARNI NG.
M
ADDED:
" ALTERNAT I VELY - FM ONLY"
REMOVED: MODE L S KSQ, KST,
KSZ, KZQ AND KZT
I NTRI NSI CALL Y
SAFE
BARRI ER
LI M I TI NG VA LUES
Voc ≤ 28. 6V Ca ≥ 5nF
I s c ≤ 1 40m A La ≥ 434µH
LTERNAT I VELY - FM ONLY
A
Voc ≤ 22V Ca ≥ 5nF
I s c ≤ 1 40m A La ≥ 434µH
P/ N 99- 5031- 000
TI TLE
UNLESS OT HERW IS E SPECIFI ED:
PLAI N DI MEN SI O N S I N I NCHES; () OR
SYSTEM DRA W I NG
" mm " D I MEN SI ON S I N MILLI METERS
E S II / E Z MODULEVE L
REMOVE A LL BURRS AND SHARP
EDGES, MA X . A LL OW ED . 032( 0,81 )
I NSI DE RAD II . 032( 0,81 ) R.
DRAW N
DATE
D. PASHOLK
ALL FI NIS HES 1 25
OR BETTER
CHKD
DATE
J . M . J ARAS
2 P L . I N. DE C. ± 0. 015 I N. ( 0, 4mm )
TOLERANCES:
3 P L . I N. DE C. ± 0. 005 I N. ( 0, 2mm )
APPD
DATE
P. S. SNI DER
5- 14- 99
PROJ NO .
SKETCH NO .
3057 - 515
SYM
DESCRI PTI ON
SEE SHEET 1 FOR REV.
M
NON HAZARDOUS LOCATI ONS
Li m i t in g Val ues
The vol t age ( Vmax) and curre n t ( I max) whi ch t he tr a ns m i tter can re cei ve
m ust be equal to or gre ater t han t he maxi m um open ci r cui t vol t age
( Voc or Vt) and t he maxi m um s hort ci r cui t curre n t ( I s c or I t) whi ch
can be del i vered by t he sour c e dev i ce. I n addi t i on, t he maxi m um
capaci t ance ( Ci ) and in duct ance ( Li ) of t he l oad and t he capaci t ance
and in duct ance of t he in ter c onnect in g w i r in g, m ust be equal to or
l ess t han t he capaci t ance ( Ca) or t he in duct ance ( La) whi ch can be
dr i ve n by t he sour c e dev i ce.
I NTRI NSI CALL Y
SAFE
BARRIE R
Li m i t in g Val ues
Voc <= 28.6V Ca >= 5 nf + Ccabl e
I s c <= 1 40 m A La >= 434 uH + Lcabl e
ALTE RNATI VLY - FM ONLY
Voc <= 22V Ca >= 5 nf + Ccabl e
M
I s c <= 1 65 m A La >= 434 uH + Lcabl e
P/N 99-5031-
000
TIT L E
UNLESS OTHERW I SE SPECI FIE D:
PLAI N DI M ENSI ONS I N I NCHES; ( ) OR
SYSTEM DRAW I NG
" mm " DI M ENSI ONS I N M I LL I M ETE RS
ES II / EZ M ODULEVEL
REM OVE ALL BURRS AND SHARP
EDGES, M AX. ALL OW ED . 032( 0, 81)
I NSI DE RADII . 032( 0, 81) R.
DRAW N
DATE
D. PASHOLK
ALL FI NI SHES 1 25
OR BETTE R
CHKD
DATE
J . M . J ARAS
TOLERANCES:
2 P L . I N. DEC. ± 0 . 015 I N. ( 0, 4mm )
3 P L . I N. DEC. ± 0 . 005 I N. ( 0, 2mm )
APPD
DATE
5-1 4-99
P. S. SNI DER
PROJ N O.
SKETCH N O.
305 7-515
48-618 ES/EZ Modulevel Displacer Level Transmitter (Top Hat Assembly Design)
REV ISI ON S
BY & DATE
CHANGE NO .
DPP 3/ 99
5057 - 008
SC 6- 99
3057 - 986
J S 11 - 99
3057 - 994
J M J ARAS
3051- 004
1- 18- 00
RC 01- 02
3051- 020
AGENCY LIS T ED
DRAW I NG
ALL REV I SI ON S TO T HIS
DRAW I NG RE QUI RE
QA APPROVA L
R
5300 BELMONT ROAD, DO W NERS GROVE,
ILLI NO IS 60515 / AREA 630 / 969- 4000
3/ 8/ 99
SCALE
PAGE
OF
2
4/ 28/ 99
NONE
1
DW G
SI ZE
99- 5031
C
REVI SI ONS
BY & DATE
CHANGE N O.
3051-0 20
RC 1-0 2
AGENCY LI STE D
DRAW I NG
ALL REVI SI ONS TO THI S
DRAW I NG REQUI RE
QA APPROVAL
R
5300 BELM ONT ROAD, DOW NERS GROVE,
I LL I NOI S 60515 / AREA 630 / 9 69- 4000
3/ 8/99
4/ 28/99
SCALE
NONE
PAGE
2
OF
2
DW G
SI ZE
99-5031
C