Deprag AST11-1 Operating Instruction Booklet page 89

Sequence controller
Table of Contents

Advertisement

• Differential torque lower limit
Lower limit of the differential end moment. The actual torque lower limit results from
the sum of the lower limit of the friction moment and the lower limit of the differential
moment.
• Differential torque upper limit
Upper limit of the differential end moment. The actual torque upper limit results from
the sum of the upper limit of the friction moment and the upper limit of the differential
moment.
• Torque hold time
A holding time can be defined to keep the moment for this time.
• Final values type: Differential torque / total torque
Selectively the end torque can be displayed as difference between the total torque
and the torque of the previous level or as total torque in the end values.
• Angle supervision: active / inactive
Monitoring of the angle with a window angle if the angle monitoring is switched on,
the following parameters are added:
◦ Angle upper limit
Upper limit of the end angle. The value counts starting from the end of the friction
measurement.
◦ Angle lower limit
Lower limit of the end angle. The value counts starting from the end of the friction
measurement.
89

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ast11-2-sAst11-1-sAst11-2

Table of Contents