Balancing Menu; Load Project Item; Ampl. & Phase Measur. Item; Balancing Item - Adash 4300 - VA3 User Manual

Vibration analyser
Hide thumbs Also See for 4300 - VA3:
Table of Contents

Advertisement

Adash Ltd.
A4300 - VA3 - Balancing

Balancing Menu

Select the Balancing item from instrument main menu. Then the Main menu of balancing appears.
- by using up/down arrows select required item and then press right arrow, ENTER or START
- by using left arrow or ESC return to main menu.

Load project Item

A project is loaded from the data instrument memory (12MB) to the balancing instrument memory.
Select required project name and confirm by ENTER.
Ampl. & Phase measur. Item
It enables on-line measurement of amplitude, phase and machine speed. Description of these items –
see [1], chapter Analyser Menu / Ampl. & phase measur. Item. These measurements can be made
before creation of a new project and before balancing procedure – see chapters New project Item,

Balancing Item.

Balancing Item
This is the main balancing process.
Before creation of a new balancing process or when you continue with process it is sensible to check
whether the amplitude and phase is equal with initial condition.
- by right arrow, ENTER or START button the first measurement screen occurs. Screen is empty for
new project without measurements.
- by using PdDn and PgUp you can display next or previous measurement screens.
- every measurement starts by START button.
7
Adash Ltd., Czech Republic, Tel.: +420 59 6232670, Fax: +420 59 6232671, e-mail: info@adash.cz
For further technical and contact information consult www.adash.net, www.adash.cz

Advertisement

Table of Contents
loading

Table of Contents