Weight Splitting - Adash 4300 - VA3 User Manual

Vibration analyser
Hide thumbs Also See for 4300 - VA3:
Table of Contents

Advertisement

Adash Ltd.
A4300 - VA3 - Balancing
Both balancing masses/angles are displayed in result field. Use right/left arrow to look at it. Install
these masses to required position.
No result is known now.
In the moment results for both planes are known.
Test measurement
Use PgDn and switch to test meas. screen. Press START and run test measurement in one plane.
Then switch to opposite plane and repeat the measurement. When vibration levels are acceptable
then the balancing process is finished. When the amplitudes are still high then use the TRIM #1, #2 ...
for next development.
When you are not satisfied, then in this moment both TRIMs #1 are calculated. Install these masses
and repeat test measurement on next screen.
Notice: Don't remove any formerly installed weights now!
No TRIM is known now.
In the moment TRIM for both planes is known.

Weight splitting

It is often the case, for example on a fan, that the balance solution requires the location of a mass in
an impossible position – in between two blades for example. To resolve this problem you will need to
use the weight splitting function.
When you press Info button on any screen, then the weight splitting screen appears. When you do
this from a screen which displays a balance solution, then this result is copied automatically to the
weight splitting screen. By using up/down arrows and ENTER button set the directions (deg) for both
locations. Weight splitting is calculating.
When the Info button is pressed, the result (0.358 oz/-23.4 deg) values are displayed on weight
splitting screen.
12
Adash Ltd., Czech Republic, Tel.: +420 59 6232670, Fax: +420 59 6232671, e-mail: info@adash.cz
For further technical and contact information consult www.adash.net, www.adash.cz