2.2 GEO M12-I and MSUB18-I connections

2.2.1 GEO M12-I connectors

GEOM12-I are connected through 2 captive cables and 2 fast connectors.
In order to connect for installation:
-
Remove the connecting plate.
Pass the cables through the cable-gland (maximum cable outside diameter is 12mm / 0.5", maximum
-
gauge wire is 2.5 mm
-
Prepare cable as below
-
Connect to the fast connectors (+): Brown (or Red) / (-): Blue (or Black).
-
Remount the connecting plate.
-
Tight the cable-gland and adjust the length.
-
Seal the cabinet with the provided blind plug on the unused cable gland.
GEO M12 GENERAL SET-UP INSTRUCTIONS
2
/ AWG13 for solid cable and 4 mm
2
/ AWG11 for multi-stranded cable)