Page 64/90
Subsequent MSUB18-I
-
Remove the 4 corner plates (Tx30)
-
Insert the axis across front and rear rigging points, insert safety clips and secure these by bending
their legs
-
Connect subsequent MSUB18-I as with second.
Subsequent GEO M12-I
-
Position second GEOM12-I.
-
Connect both cabinets by inserting the axis through front holes and secure axis with brake nuts.
-
Adjust the appropriate inter-angle value with the linkbar and secure with the provided screws (1 x
shoulder screw (D10x20), 2 x washers (M10), 1 x brake nut (M8).
-
Connect subsequent GEO M12-I cabinets as with second.
GEO M12 HARDWARE SETUP PROCEDURE