Page 54/90
6.4.4 MSUB18 flown with Touring Bumper
Required items
-
1 or 2 hoists (not provided).
-
1 x VNT-BUMPM12
-
1 x VNT-EXBARM12 to fly on a single rigging point
When flying MSUB18 cluster, VNT-BUMPM12 must be set at 0°
-
If cluster is flown from 2 points, bumper must be maintained horizontal in its definitive
position as well as when lifting or lowering the cluster
-
If cluster is flown from a single point, extension bar must be used and hoist connected
to "G" position
Maximum MSUB18 quantity for flown vertical cluster with VNT-BUMPM12 is 8.
Please check NS-1 for mechanical Safety Working Load and acoustic computations.
Motor hoist must be rated to support entire cluster weight. Please check configuration
GEO M12 HARDWARE SETUP PROCEDURE
IMPORTANT
IMPORTANT
IMPORTANT
in NS-1 for proper motor hoist rating