2.3 Cabling

NEXO recommends the exclusive use of multi-conductor cables to connect the system: the cable kit is
compatible with all the cabinets, and there is no possible confusion between LF, MF and HF sections.
Cable choice consists mainly of selecting cables of the correct sectional dimension (size) in relation to
the load resistance and the cable length. Too small a cable section will increase both its serial resistance
and its capacitance; this reduces the electrical power delivered to the loudspeaker and can also induce
response (damping factor) variations.
For a serial resistance less or equal to 4% of the load impedance (damping factor = 25), the recommended
cable length is given by:
The table below indicates these values, for 3 common sizes.
Load Impedance ()
Cable section
1,5 mm² (AWG #14)
2,5 mm² (AWG #12)
4 mm² (AWG #10)
Maximum allowed length is 4 times recommended length.
Example:
GEO M12 module has a 8  nominal impedance in passive mode. When connecting 4 modules in parallel,
total load impedance become 2.
Recommended length for 4mm
Long speaker cables induce capacitive effects – up to hundreds of pF depending on the
quality of the cable - with a low-pass effect on high frequencies. If long speaker cables
must be used, ensure that they do not remain coiled while in use.
2.4 GEO M12 & MSUB18 recommended amplification
NEXO TD Controllers
NXAMP4x1mk2 Powered Controller Bridged Stereo mode
(2x2.6kW/4)
NXAMP4x2mk2 Powered Controller 4 channels mode
(4x2.5kW/2)
NXAMP4x4 Powered Controller 4 channels mode
(4x4kW/2)
2.5 GEO M12 & MSUB18 setups on NEXO TD Controllers
Please consult nexo-sa.com for NEXO TD Controllers firmware information.
GEO M12 GENERAL SET-UP INSTRUCTIONS
L
= Z x S
S in mm
max
2
Recommended Cable Length
3m/10ft
5m/16ft
8m/26ft
2
/ (AWG#10) is 8m / 26ft, maximum allowed length is 32m / 105ft.
2
, Z in Ohm, L
max
3
4
6
4.5m/13ft
6m/20ft
9m/30ft
7.5m/23ft
10m/33ft
15m/49ft
12m/39ft
16m/52ft
24m/79ft
IMPORTANT
Recommended amplification
2 x GEO M12 in passive mode per bridged channel
1 x MSUB18 per bridged channel
1 x GEO M12 in passive mode per channel
1 x MSUB18 per channel
3 x GEO M12 in passive mode per channel
3 x GEO M12 in active mode: 2 channels
2 x MSUB18 per channel
Page 11/90
in meters
8
12m/39ft
20m/66ft
32m/105ft