11.1. Enrollment (teaching) of wireless items

If the control panel has a 65R module, as a maximum 16
wireless detectors and 8 controllers (remote controls & keypads)
can be enrolled to the control panel. A wireless siren and an
additional JA-60 or JA-65 control panel (a subsystem) can be
enrolled as well.
Press key 1 (while „P" is displayed) to enter the enrolling
mode. The control panel will display the next free position
to enroll a detector.
If no JA-60E keypad is used in the installation and
o
you need to enroll a wireless JA-60F keypad:
connect (short ) the RESET pins on the control panel
board it will open the learning mode (tamper in the
control panel must remain opened)
install batteries to the JA-60F keypad and wait until the
keypad enrolls. Enrollment will be confirmed on the
keypad.
disconnect the RESET pins and then use the keypad
to enroll all the other items in following way
Use key 1 and 7 to scroll (up and down) all control panel
wireless positions – 1 to 16 (detectors) – c1 to c8
(controllers & keypads) – A (wireless siren) – J (sub control
panel JA-6x). The display shows the position number while
the Battery LED indicates if the position is occupied. The
system will not allow enrollment of an item into a non-
corresponding position (a detector can not be enrolled into
a controller position etc.).
Detectors and keypads are automatically enrolled when their
power is switched on (batteries are installed). A remote control
is enrolled only after both of its buttons are simultaneously
pressed and held for 3 seconds. A subsystem control panel
will enroll after sequence 299 is entered while it is in its
programming mode. The system will not allow enrollment of an
item into a non-corresponding position (a detector can not be
enrolled into a controller position etc.).
Control panel confirms enrollment with a „beep" (press F
to select a louder "beep" sound). The LED display will show
the number of the enrolled item for 2 seconds and then it
will display the number of the next free position.
To change the position of an enrolled item is simple. Enroll
it to the new selected position (the item will „move"). If you
enroll an item to an occupied position, the former item will be
deleted and only the new enrollment is valid. Only one item
(detector, controller etc.) can be stored to each position.
Erase an enrolled item the following way: in the enrolling
mode select the corresponding position and then press and
hold key 2 for two seconds. The item will be erased
(confirmed with a long beep). If you press and hold key 3, all
enrolled controllers (remote controls and keypads) will be
erased. Pressing and holding key 4 will erase all enrolled
items (detectors, controllers, siren and the sub system).
The JA-60A wireless siren will generate an enrollment
signal when its power is switched on (it will enroll to
position A). If you need to enroll a siren which is already
powered and it is not possible to easily switch off its power,
you can enroll it the following way: enter the enrolling mode
and then enter the 6 digit siren production code (printed in
the siren's manual). The control panel will "request" the
siren to send its enrollment signal. The siren will send the
signal only if it has no current communication with any other
control panel (This protects you from enrolling your
neighbor's siren). Enrollment is completed about five
seconds after the code is entered.
By pressing the button 8 in the enrolment mode the
communication quality of the items can be checked
(LED indicator "battery" will start flashing). After receiving
signal from the item the level of the signal is shown on the
display from 0 to 10 (corresponding to 0-100% in the
ComLink software). In this mode it is also possible to adjust
level of audible indications by pressing the button F and
Alarm system JA-65 MAESTRO
scroll positions of the enrolled items by pressing buttons 1
and 7. Button N exits checking mode.
enter: 1
To exit the enrolling mode press the N key
Note: If you do not use JA-60E in your installation, you can
enter the learning mode in a different way. Shorten the RESET
pins No.K11. This way the JA-60F keypad will be enrolled to the
system. You can remove the jumper now.
Note: if an item was not enrolled after its batteries were
installed, it is because the control panel recognized its radio
signal as a weak one. Items are only enrolled if their radio signal
has a level which guarantees reliable communication. Check the
detector's batteries and try to enroll the problematic sensor once
more. If it is not accepted by the control panel, you should
change the location of the item. All items should be located 1 m
or more from the control panel.

11.2. Hard-wired zone input setting

If there is a 65H module in the control panel, wire operated
detectors can be connected to the control panel. Setting of the zone
inputs is possible by entering: 60 nn xys
where:
nn
zone number: 01 to 16
x
input triggering: 0 = off, 1 = Normally Closed, 2 =
balanced loop (EOL resistor 10 kΩ), 3 = double
balanced loop (EOL resistors 2x10 kΩ)
y
reaction: 0 = Instant, 1 = Delayed, 2 = Fire, 3 = Panic, 4
= Tamper, 5 = Next delayed, 6 = control
s
address to section, 1 = A, 2 = B,
common section, which is armed only if both A and B
sections are armed). If the control panel is not split,
select s=1; if you select s=2 then this zone will be
automatically bypassed within partial arming. For
details about splitting see section 11.23.
Notes:
• If you will not use a particular input, switch it off with x = 0
• Next delayed input (y=5) provides entrance delay only if in the
moment of its triggering the entrance delay has been in
progress (activated before by any delayed input). If no
delayed input is triggered before next delayed, the triggering
will cause instant alarm.
• Addressing of inputs to section C when the control panel is not
split has the same effect as addressing to B section (i.e.
automatic bypass while partial arming is used).
• If y=6 is programmed, then each triggering of this input
changes arming status (arm – disarm – arm...) of the entire
system or just the corresponding section if the system is split.
Example: to set zone 2 input as a balanced loop with an instant
reaction, addressed to A section, enter: 60 02 201
Factory default setting: all hard-wired inputs are switched off.

11.3. Exit delay

To change the duration of the exit delay enter 20x (where x
represents time in seconds x10). The delay can be selected
from 10 to 90 seconds.
Example: to select an Exit delay duration of 20 seconds, enter 202
Factory default setting is 30 seconds
- 9 -
sequence: 60 nn xys
3 = C (shared
sequence: 2 0 x
MFM53003