Enrollment Of A Telephone; Communication Test; Settings - jablotron Azor User Manual

Wireless gsm mini alarm for monitoring against burglars
Hide thumbs Also See for Azor:
Table of Contents

Advertisement

Enrollment of a telephone

 The GSM control unit must be switched on and all its indicator lights must be flashing
green.
Call Azor (its SIM card number) from the telephone (A)
 As soon as the GSM LED indicator starts flashing red (B), press the GSM control unit
button (C) for a short time.
 The GSM LED indicator should confirm call reception by flashing blue.
 Azor then plays the voice menu to the telephone (D).
Test the menu functions and end the call.
 In order to access the menu repeatedly, just call Azor again (from the same telephone
number).
Tips and specifications
Only one telephone without a hidden number can be enrolled.
When the telephone is being enrolled, Azor must be unset.
Only the first user's telephone can be enrolled in the above-mentioned way.
You can use the same way to replace the first user's telephone number with another one.
The originally enrolled telephone number is then deleted (Azor will send an SMS notification
– including the number of the newly set telephone).
Azor should set the language automatically based on your country calling code.
For the setting of other users' telephones and their locking, see the Settings.
- 12 -

Communication test

Call Azor from an enrolled telephone (A).
 Press 9 (C) in the voice menu (B).
 Detector testing mode should be activated.
 Activate the detectors and the RFID tag reader one after another (D).
 Test a motion detector by opening and closing its cover.
 Test a door-opening detector by opening and closing its cover.
 Press the UNSET button to activate the RFID tag reader.
 Azor will confirm detector activation with a voice message to the user's telephone
number.
 End the call to finish testing or press # on the phone keypad.
Tips and specifications
The test can start only when Azor is unset
If Azor fails to send a report confirming detector activation, check:
 whether the detector batteries have been installed properly.
 whether radio communication is shielded by a metal obstacle.
 whether the distance between the detector and the GSM control unit is too far (try a
different location).
 whether the detector has been enrolled correctly (by connecting to a computer and
checking the registration code).
 it is not possible to set the system during test mode and no alarm can be triggered
Azor regularly checks its connection to the detectors and the RFID tag reader. If the connection is lost, a
report is sent to the user (must be set) and information is also stored in the event memory. In such a
case please check the batteries in the detector or RFID tag reader concerned and check the signal level
(it may be influenced e.g. by changes in the room arrangement).