10.1 Enrollment (teaching) of wireless items
The wireless control panel (63KR or 63KRX) can enroll up to 32 wireless detectors (2 in each zone), up to 8 controllers
(remote controls & keypads), wireless sirens and an additional JA-6x control panel as subsystem:
• Press key 1 (while „P" is displayed) to enter the enrolling mode. The control panel will display the next free position
to enroll a detector.
If no JA-60E keypad is used in the installation and you need to enroll a wireless JA-60F keypad:
o
• Use key 1 and 7 to scroll (up and down) all control panel wireless positions – 1 to 16 (detectors) – c1 to c8
(controllers & keypads) – A (wireless siren) – J (sub control panel JA-6x). The display shows the position number
while the Battery LED indicates if the position is occupied. The system will not allow enrollment of an item into a non-
corresponding position (a detector can not be enrolled into a controller position etc.).
• Detectors and keypads are enrolled after their power is switched on (batteries are installed). A remote control is
enrolled after both of its buttons are simultaneously pressed and held for 3 seconds. A subsystem control panel will
enroll after sequence 299 is entered while it is in its programming mode.
• Control panel confirms enrollment with a „beep" (press F to get confirmation by a wired siren). The display will
show the number of the enrolled item for 2 seconds and then it will display the next free position.
• Second detector enrolment to a zone – select the zone into which you want enroll the second detector. Press
shortly key 5 (selects second position) and then install battery to the detector. Enrollment of the second detector will
be indicated by the Fault LED. If there are two detectors in a zone, all indicators in this zone (alarm, tampering, low
battery etc.) will be common for both enrolled detectors (for example, if any of the two detectors is tampered with, the
zone will indicate tampering.).
• To change the position of an enrolled item - simply enroll it to the new selected position (the item will „move"). If
you enroll an item to an occupied position, the former item will be deleted and only the new enrollment is valid.
Normally only one item (detector, controller etc.) can be stored to each position.
• Erase an enrolled item by selecting the corresponding position and then press and hold key 2 for two seconds. The
item will be erased (confirmed with a long beep). If you press and hold key 3, all enrolled controllers (remote controls
and keypads) will be erased. Pressing and holding key 4 will erase all enrolled items (detectors, controllers, siren and
the sub system). If two detectors were enrolled in a zone, both of them will be erased if you erase the zone's position.
• The JA-60A wireless siren will enroll (to position A) when its power is switched on. If you need to enroll a siren
which is already powered and it is not possible to easily switch off its power, you can enroll it the following way: enter
the enrolling mode and then enter the 6 digit siren production code (printed in the siren's manual). The control panel
will "request" the siren to enroll. The siren will do that only if it has no current communication with any other control
panel (This protects you from enrolling your neighbor's siren).
• Multiple outdoor sirens or multiple subsystems enrolment – enter 000000 while in enrolling mode. After this
outdoor sirens and JA-6x subsystems can be enrolled to positions 1 to 16.
• By pressing the button 8 in the enrolment mode the communication quality of the items can be checked
(LED indicator "battery" will start flashing). After receiving signal from the item the level of the signal is shown on the
display from 0 to 10 (corresponding to 0-100% in the ComLink software). In this mode it is also possible to adjust
level of audible indications by pressing the button F and scroll positions of the enrolled items by pressing buttons 1
and 7. Button N exits checking mode.
• To exit the enrolling mode press the N key
Note: if an item was not enrolled after its batteries were installed, it is because the control panel recognized its radio signal as a
weak one. Items are only enrolled if their radio signal has a level which guarantees reliable communication. Check the detector's
batteries and try to enroll the problematic sensor once more. If it is not accepted by the control panel, you should change the location of
the item. All items should be located 1 meter as minimum from the control panel.
10.2 Hard-wired zone input setting
If the hard wired L1 to L4 zones are used, their features can be programmed by entering:
60 nn xys
where: nn = zone number: 01 to 16
x = input triggering: 0 = off, 1 = Normally Closed, 2 = balanced loop (EOL resistor 2k2), 3 = double
balanced loop (EOL resistors 2x 1k1)
y = reaction: 0 = Instant, 1 = Delay, 2 = Fire, 3 = Panic, 4 = Tamper, 5 = Next delay, 6 = Arming control
s = address to section, 1 = A, 2 = B, 3 = C (shared common section, which is armed only if both A and B
sections are armed). If the control panel is not split, select s=1; if you select s=2 then this zone will be
automatically bypassed within partial arming. For details about splitting see section 10.22.
Notes:
• If you will not use a particular input at all, you can switch it off completely with parametr x = 0
JA-63 „PROFI" Alarm System
connect (short ) the RESET pins on the control panel board (it will open the learning mode)
install batteries to the JA-60F keypad and wait until the keypad enrolls. Enrollment will be
confirmed on the keypad.
disconnect the RESET pins and then use the keypad to enroll all the other items in following way
- 10 -
enter: 1
sequence: 60 nn xys
MGK51404

Advertisement

Table of Contents
loading

Table of Contents