Special Set-Up Procedure
WARNING – Turn off electrical power and disconnect power cord from electrical supply before
beginning Special Set-Up Procedure. If power cord is not disconnected, severe injury to
personnel could result.
Changing the Tape Leg Length
(From 70 to 50 mm [2-3/4 to 2 inch])
The following changes to the case sealer frame and upper/lower taping heads will allow the taping of boxes
90 mm [3.5 inch] minimum height.
CASE SEALER FRAME
(Refer to Figure 6-1A)
1. Raise the upper head assembly by turning crank handle counterclockwise. Remove and retain the two
screws and washers that secure the stop bracket in position "A".
2. Remount and secure the stop bracket in the lower position "A-A" with original fasteners through top holes of
stop bracket. Relocate both right and left stop brackets.
Figure 6-1 – Case Sealer Frame Changes
25