PROBLEM
1 Power to machine is off.
2 Freeze-up (auger will not turn).
Machine does not
run.
3 Front door not in place.
1 Consistency temperature setting is too
Machine will not
shut off.
2 Refrigeration problem.
1 Consistency temperature setting is too
Product is too fi rm.
1 No vent space for free fl ow of cooling
2 Condenser is dirty.
3 Consistency setting too soft.
Product is too thin.
4 Auger is assembled incorrectly.
5 Auto Fill Pump not operating.
6 Refrigeration problem.
1 No mix in hopper.
2 Drive motor overload tripped.
Product does not
dispense.
3 Drive belt failure.
4 Freeze-up (Auger will not turn).
1 Worn drive belt.
Drive belt slipping
2 Freeze-up (Auger will not turn).
or squealing.
3 Not tensioned properly.
1 Outside surface of rear auger seal is
Rear auger seal
2 Rear seal missing or damaged.
leaks.
3 Seal o-ring missing, damaged or
4 Worn or scratched auger shaft.
1 Front door knobs are loose.
2 Spigot parts are not lubricated.
3 Chipped or worn spigot o-rings.
Front door leaks.
4 O-rings or spigot installed wrong.
5 Inner spigot hole in front door nicked
Owner's Manual #513667
POSSIBLE CAUSE
fi rm.
fi rm.
air.
lubricated.
installed incorrectly.
or scratched.
1 Supply power to machine.
2 Turn off barrel for 15 minutes by pressing the
On/Off Left or On/Off Right button, then restart.
3 Assemble front door in place.
1 Turn Consistency Adjustment screw counter-
clockwise.
2 Check system. (Call distributor for service)
1 Turn Consistency Adjustment screw counter-
clockwise.
1 A minimum of 6" of air space on both sides.
(See Section 2)
2 Clean. (See Section 3)
3 Turn Consistency Adjustment screw clockwise.
4 Remove mix, clean, reassemble, sanitize and
freeze down.
5 See Auto Fill Troubleshooting section.
6 Check system. (Call distributor for service)
1 See Auto Fill Troubleshooting section.
2 Wait for automatic reset. (If condition
continues, call distributor for service.)
3 Replace drive belt.
4 Turn off cylinder, wait for 15 minutes, then
restart.
1 Replace drive belt.
2 Turn off cylinder, wait for 15 minutes, then
restart.
3 Adjust belt tension
1 Clean lubricant from outside of rear seal and
thoroughly clean rear of freezing cylinder.
Lubricate inside of seal and reinstall.
2 Check or replace.
3 Check or replace.
4 Replace auger shaft.
1 Tighten knobs.
2 See Section 3.
3 Replace o-rings.
4 Remove spigot and check o-ring.
5 Replace front door.