Figure 3-2 IntelliTec2 Control
A. INTELLITEC2 TOUCHPAD
Main Power On/Off
The Main Power button is used to supply power to the
IntelliTec2 control, the freezing cylinder circuits and the
storage refrigeration system. When the machine is fi rst
plugged in, the control defaults to the On status with power
to the hoppers only. If the Main Power On/Off button is
pressed when the machine is on, the machine will turn
off and a status message will be displayed on the screen.
Help
Pressing the Help button will display help information
dependant on the cursor's location. Pressing the Help
button again will exit the help screen.
Selection Button (SEL)
The SEL button is used by service technicians to select
menu options.
Set Button (SET)
The SET button is used by service technicians to save
changes when modifying control settings.
On/Off Button
Power to the freezing cylinders is controlled with the On/
Off Left and On/Off Right buttons.
Push to Freeze Button
Pressing the PUSH TO FREEZE button initiates "Serve
Mode".
Clean Button
The CLEAN button initiates "Clean Mode".
Pump Button
The Pump On/Off buttons control power to the solenoids
for the autofi ll system.
Arrow Buttons ()
The arrow buttons are used by service technicians to
navigate through the control readings and settings.
Owner's Manual #513667
B. SPIGOT SWITCH
The spigot switch will automatically start the auger drive
and refrigeration systems when the spigot is opened to
dispense product. When the spigot is closed, the drive
motor and compressor will remain on until the product
in the freezing cylinder reaches the proper consistency.
C. CONSISTENCY ADJUSTMENT SCREW
The Consistency Adjustment Screw increases or decreas-
es product consistency. A tension spring is connected to
the screw and changes the amount of torque needed to
complete a refrigeration cycle. Turn the knob clockwise
to increase consistency or counterclockwise to decrease
consistency.
C. HOPPER PROBES
The mix level in the hoppers is controlled by two probes.
When mix in the hopper gets below the long probe, the
autofi ll solenoid opens and the hopper fi lls. When the mix
level reaches the short probe, the autofi ll solenoid closes.

3.3 REMOVING MIX FROM MACHINE

To remove the mix from the machine, refer to the follow-
ing steps:
A.
Wash, rinse, dry and sanitize hands before
starting.
B.
Press the Pump On/Off button to turn the autofi ll
pump off.
C.
Make sure the display shows the freezing cylinder
is off. If it is not, press the On/Off Left or On/Off
Right button to turn it off.
D.
Press the Clean button and drain the mix from
the freezer into a bucket. Once drained, stop the
cleaning cycle by pressing the Clean button.
E.
Fill the hopper with 2 gallons of clean, cold water.
F.
Press the Clean button. Run the machine in Clean
mode for approximately 5 minutes. Continue to
the next step while the machine is cleaning.
G.
Prepare Stera-Sheen Green Label Sanitizer
according to manufacturer's instructions to
provide a 100ppm strength solution. In a clean
bucket, mix 1 packet of sanitizer and 2 gallons
of cold water. Check the chlorine content with a
test strip to ensure 100ppm strength.
H.
After 5 minutes, drain the water from the machine
into a bucket and discard the water. Press the
Clean button to stop the cleaning cycle.
If the water does not drain clear, repeat the steps.
I.
Fill the hopper with the 2 gallons of sanitizer
solution.
J.
Press the clean button. Run the machine in Clean
mode for approximately 5 minutes.
10