Electrical Connection; Semiconductor Output; Test Input - Cedes TLS 600 Installation And Operation Manual

Hide thumbs Also See for TLS 600:
Table of Contents

Advertisement

TLS 600

8. Electrical connection

U
(10 ... 30 VDC)
SP
TLS 600
GND (0 VDC)
Output

Test input

Figure 14: TLS 600 connection diagram

8.1 Semiconductor output

The TLS 600 is available as a PNP or NPN version
with either a dark-on (DO) or light-on (LO) type.
The DO output is ON when an object or person is
detected, OFF if the detection area is free. The LO
output is OFF when an object or person is detected,
ON if the detection area is free  Chapter 9.
NOTICE
Possible damage to the
semiconductor output
PNP outputs need a pull-down resistor
(10 ... 47 kΩ)
NPN outputs need a pull-up resistor
(10 ... 47 kΩ)
8
brown
blue
black
white
If no test signal is available,
connect the white wire to U
8.2 Test input
TLS 600 performs a test cycle as follows: The
illumination is switched off and the sensor recognizes
the change and switches the output.
Important: Please be aware that the TLS 600 must
always have a background (floor)
Controller
SP
.