3. Electrical connection and output signals

3.1. Connection diagram

Figure 5: Connection diagram

3.2. Output signals

The following diagram shows the output signal behavior based on an object detection or test input signal.
Figure 6: Timing diagram

3.3. Test Input

A test cycle works as follows: The emitter is
switched off and the output recognizes the change
and switches the output.
Important:
Please be aware that this works only with the N- and
P-type
when
they
The test input cannot be used with the VR-type and
has to be connected to the Usp.

4. Start-Up and LED status

4.1. Start-Up

1. Switch on mains and/or power up the door
control unit.
2. After start-up, an LED comes on.
3. It is recommended to perform a test procedure
with the door control unit using the test input.
Important:
Check the detection area of the sensor. If
adjustments are needed, please switch off main
© CEDES/May 2011
If no test signal is available  White to U
"see"
the
floor.
www.cedes.com
SP
power and/or the door controller again for your own
safety.

4.2. LED status

The TLS 500 has a red and a green LED to indicate
its status which is dependent on the type.
TLS 500 type Field free
PNP-DO
Red LED on
PNP-LO
Green LED on
NPN-DO
Red LED on
NPN-LO
Green LED on
Example for a TLS 500 N-NPN-LO:
1. The TLS 500 shows via a green LED that there is
no object disrupting the detection area.
2. When a person enters the detection area the
TLS 500 switches the output and the LED to red.
3. The sensor cannot differenciate between an
object and a person. Therefore any object
entering the detection field is also detected.
4. When an object or person does not move for
more than 10 s, the TLS 500 accepts this object
TLS 500
Time
Power-up
t
< 150 ms
1
time
Response
< 150 ms
t
2
time
t
< 150 ms
Release time
3
Test
< 150 ms
t
response
4
time
t
Test time
5
Value
≥ U
Output HIGH
SP
< 4 V
Output LOW
Object detected
Green LED on
Red LED on
Green LED on
Red LED on
Value
> t
4
- 4 V
5

Advertisement