Tls 600 Product Overview; Detection Area Dimensions; Configuration; Background Influence - Cedes TLS 600 Installation And Operation Manual

Hide thumbs Also See for TLS 600:
Table of Contents

Advertisement

TLS 600

5.2 TLS 600 product overview

2
1
5
Figure 6: TLS 600 overview
1
Mounting bracket
2
TLS 600 sensor
3
Potentiometer
4
Connection cable
5
Adjusting screw
6
Optical window

5.3 Detection area dimensions

The detection area dimensions of the sensor depend
on the distance to the object or background. All
measurements in mm (normal numbers) and
inches (in brackets).
Figure 7: Detection area dimensions at 2 m (6.6 ft)
6
3
4

6. Configuration

NOTICE
Mechanical damage to the TLS 600
Do not turn the potentiometer beyond its
mechanical limit
The recalibration time can be adjusted from 3 s up to
180 s by turning the potentiometer.
Recalibration time means the time until an immobile
person or object is accepted by the sensor as
background.
10 s
6
3 s
Figure 8: Configuring the TLS 600 P-type (in seconds)

6.1 Background influence

TLS 600 has a maximal operating range of 4 m
(13 ft) on Kodak white. However, different floor
materials and colors influence the effective operating
range. See table below for reference.
Material
Kodak white
Bright wood
Brown cardboard
Kodak grey
Bright concrete
Dark carpet
Applies only when beam axis is perpendicular to surface
30 s
60 s
180 s
Max. detection range
4 m (13 ft)
2.8 ... 3.2 m (9 ... 10.5 ft)
2.8 ... 3.2 m (9 ... 10.5 ft)
2.4 m (8 ft)
2.4 ... 3.2 m (8 ... 10.5 ft)
1.2 ... 2 m (4 ... 6.5 ft)
© CEDES | V 1.0

Advertisement

Table of Contents
loading

Table of Contents