Advertisement

Note
The wall mounting must be capable of supporting at least four times the weight of the device.
5.5

Grounding

Installation on a DIN Rail
The device is grounded over the DIN rail.
S7 Standard Rail
The device is grounded over its rear panel and the neck of the screw.
Wall Mounting
The device is grounded by the securing screw in the unpainted hole.
Please note that the SCALANCE X108 must be grounded over one securing screw with
minimum resistance.
5.6

Fitting the IE FC RJ-45 Plug 180

Assembly of the IE FC RJ-45 Plug 180 on an IE FC Standard Cable
For information on assembling an IE FC RJ-45 Plug 180 on a SIMATIC NET Industrial
Ethernet FastConnect cable, please refer to the instructions supplied with the IE FC RJ-45
Plug.
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
Commissioning Manual, 1,
Installation and Maintenance
5.5 Grounding
5-5