Siemens SCALANCE X-100 Commissioning Manual page 58

Scalance industrial ethernet product line
Hide thumbs Also See for SCALANCE X-100:
Table of Contents

Advertisement

Product Characteristics
4.5 SCALANCE X204-2
0 – 85 m
0 -3,000 m
Aging time
Aging time
Permitted Environmental Conditions / EMC
Operating temperature
Storage/transport temperature
Relative humidity in operation
Operating altitude
RF interference level
Noise immunity
Degree of protection
Approvals
c-UL-us
c-Ul-us for hazardous locations
FM
C-TICK
CE
ATEX Zone 2
MTBF
MTBF
Construction
Dimensions (W x H x D) in mm
Weight in g
Installation options
Order Numbers
SCALANCE X204-2
"Industrial Ethernet TP and Fiber Optic Networks"
manual
IE FC Stripping Tool
4-44
IE FC marine/trailing cable with IE FC RJ-45 plug
180
or
IE FC marine/trailing cable (0 - 75 m) + 10 m TP
cord
Glass FOC
62.5/125 µm or 50/125 µm glass fiber;
≤ 1 dB/km at 1300 nm;
600 MHz x km;
6 dB max. permitted FO cable attenuation with 3
dB link power margin
5 minutes
0° C through +60° C
-40° C through +80° C
‹ 95% (no condensation)
2000 m at max 56 °C ambient temperature
3000 m at max. 50 °C ambient temperature
EN 50081-2 Class A
EN 50082-2
Tested to IP30
UL 60950
CSA C22.2 No. 60950
UL 1604, UL 2279Pt.15
FM 3611
AS/NZS 2064 (Class A).
EN 50081-2, EN 50082-2
EN50021
37.56 years
60 x 125 x 124
780
DIN rail
S7-300 standard rail
Wall Mounting
6GK5204-2BB00-2AA3
6GK1970-1BA10-0AA0
6GK1901-1GA00
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line