Scalance X206-1 Displays - Siemens SCALANCE X-100 Commissioning Manual

Scalance industrial ethernet product line
Hide thumbs Also See for SCALANCE X-100:
Table of Contents

Advertisement

Product Characteristics
4.4 SCALANCE X206-1
Notice
The C-PLUG may only be inserted or removed when the power is off!
Removing the C-PLUG
It is only necessary to remove the C-PLUG if the basic device develops a fault.
The C-PLUG can be removed from the slot using flat pliers, tweezers, or a small screwdriver.
4.4.9

SCALANCE X206-1 Displays

Fault indicator (red LED)
Status
lit red
flashes red
not lit
Power indicator (green LED)
The status of the power supply is indicated by two green LEDs:
Status
lit green
not lit
Port status indicator (green/yellow LEDs)
The status of the ports is indicated by seven two-color LEDs:
Status
Port 1 through 8 LED lit green
Port 1 through 8 LED lit yellow
4-32
Meaning
The SCALANCE X206-1 detects an error. At the same time, the
signaling contact opens.
The following faults are detected:
1. Link down event on a monitored port
2. Failure of one of the two redundant power supplies.
3. Device startup, the LED is lit for approx. 20s.
An internal fault was detected.
Notify the maintenance personnel and, if necessary, send the
device in for repair.
No fault detected by the SCALANCE X206-1.
Meaning
Power supply L1 or L2 is connected.
Power supply L1 and/or L2 not connected or <14 V.
Meaning
TP link exists, no data reception
TP link exists, data received at TP port
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
Commissioning Manual, 1,