Procedure
Follow the steps below to configure a device:
1. Click on the plus symbol in front of the device symbol or double-click on the device
2. Click on the interface you want to configure. The Primary Setup Tool displays the input
3. Decide how the device will obtain its IP address:
4. Make the following entries if you have decided to assign the IP address manually:
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
Commissioning Manual, 1,
symbol to display all interfaces of the device.
dialog for the configuration data in the right-hand pane of the program window.
Depending on the selected settings, some text boxes or check boxes may be disabled.
The MAC address box is always disabled because this address is a property of the
device that cannot be modified. The Client ID parameter and DNS is also not supported
by the SCALANCE X-200.
– Dynamically from a DHCP server:
Select the Obtain IP address from DHCP server option button.
– Manual assignment by the user:
Select the Assign IP parameters option button.
– Enter the IP address for the device in the IP Address box. In each subarea separated
by periods, you can enter a number between 0 and 255, other entries are rejected by
the program.
– Enter the subnet mask in the subnet mask box.
– When necessary, select the Router check box and enter the IP address of the router
in the relevant text box. The information on the router is necessary if the computer
with which you are creating the configuration is not in the same subnet as the device
you are configuring.
Diagnostics over Industrial Ethernet
6.1 Configuration with the Primary Setup Tool
6-5