Scalance X108 Technical Specifications - Siemens SCALANCE X-100 Commissioning Manual

Scalance industrial ethernet product line
Hide thumbs Also See for SCALANCE X-100:
Table of Contents

Advertisement

Product Characteristics
4.1 SCALANCE X108
Power indicator (green LED)
The status of the power supply is indicated by two green LEDs:
Status
lit green
not lit
Port status indicator (green/yellow LEDs)
The status of the ports is indicated by eight LEDs:
Status
Port 1 through 8 LED lit green
Port 1 through 8 LED lit yellow
Ports 1 through 8 LED flash yellow
4.1.8

SCALANCE X108 Technical Specifications

Technical Specifications of the SCALANCE X108
Ports
Attachment of DTEs or network components over
twisted pair
Connector for power supply
Connector for signaling contact
Electrical Data
Power supply
Power loss at DC 24 V
Current consumption at rated voltage
Overvoltage protection at input
Permitted Cable Lengths
Network span parameter/TP cable length
0 – 100 m
0 – 85 m
4-6
Meaning
Power supply L1 or L2 is connected.
Power supply L+ is not connected or <14 V
Meaning
TP link exists, no data reception
TP link exists, data received at TP port
Setting or display of the fault mask
8 x RJ-45 sockets with MDI-X pinning 10/100
Mbps (half/ full duplex)
1 x 4-pin plug-in terminal block
1 x 2-pin plug-in terminal block
2 x 24 V DC
(18 - 32 V DC)
safety extra-low voltage (SELV)
3.36 W
140 mA
PTC resetable fuse (0.6 A / 60 V)
IE FC standard cable with IE FC RJ-45 plug 180
or
over IE FC outlet RJ-45 with 0 - 90 m IE FC
standard cable + 10 m TP cord
IE FC marine/trailing cable with IE FC RJ-45 plug
180
or
0 - 75 m IE FC marine/trailing cable + 10 m TP
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
Commissioning Manual, 1,

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance x-200

Table of Contents