Cellular Receiver 2 Options; Command And Control Options; External Event Label Programming - DSC 3G2080 Installation Manual

Cellular alarm communicator - international, internet and hspa dual-path alarm communicator
Hide thumbs Also See for 3G2080:
Table of Contents

Advertisement

[205] Cellular Receiver 1 APN Default ( )
32 ASCII characters.
____________________________________
[206] Cellular Receiver 1 Domain Name
Default ( )
32 Character ASCII characters.
____________________________________

Cellular Receiver 2 Options

[211] Cellular Receiver 2 Account Code
Default (0000000000)
Valid range: 0000000001 - FFFFFFFFFE.
[212] Cellular Receiver 2 DNIS
Default (000000)
Valid range: 000000 - 0FFFFF.
[213] Cellular Receiver 2 Address
Default (000.000.000.000)
[214] Cellular Receiver 2 Port
Default (0BF5/3061) Valid range: 0000 - FFFF.
[215] Cellular Receiver 2 APN
Default ( ) 32 ASCII characters.
____________________________________
[216] Cellular Receiver 2 Domain Name
Default ( )
32 ASCII characters.
____________________________________
Cellular Options
[221] Cellular Public Access Point Name
Default ( ) 32 ASCII characters
____________________________________
[222] Cellular Login User Name
Default ( ) 32 ASCII characters.
____________________________________
[223] Cellular Login Password
Default ( ) 32 ASCII characters.
____________________________________
[224] Cellular Test Transmission Time of Day
Default (9999) Valid range: 00 - 23 hrs. (HH) 00 - 59 min.
(MM).
[225] Cellular Test Transmission Cycle
Default (000000)
Valid range: 000000 - 999999 minutes.
[226] Network Trouble Delay
Default (0F)
Valid entries from, 00 to FF.

Command and Control Options

[301] Command and Control Toggle Options
[1] SMS Notification (ON).
[2] Reserved
[3] SMS Command and Control Default (ON).
[4] Reserved
[5] SMS Character Format (OFF)
[6] Long SMS Message Handling Default (OFF).
[7] Reserved
[8] Reserved
[311]-[342] SMS Phone Number 1-32
______________________________________________
[343]-[374] SMS Phone Number 1-32 Toggle
Options
[1] SMS Notification Alarm/Restore Default (OFF).
[2] Reserved
[3]SMSNotification Opening/ClosingDefault(OFF).
[4] Reserved
[5] SMS Notification System Test Default (OFF)
[6] SMS Notification Internal Events Default (OFF).
[7] SMS Notification Enabled Default (OFF).
[8] SMS Command and Control Enabled Default
(ON).
[375]-[406] SMS Phone Number 1-32 Partition
Options
Default (00) Valid range: 00 - FF.
00 - Global; 01-32 - Partition; FF - Disabled

External Event Label Programming

[451] Burglary Alarm
Default (Burglary Alarm)
______________________________________________
[452] Burglary Alarm Restore
Default (Burglary Alarm Restore)
______________________________________________
[453] Fire Alarm
Default (Fire Alarm)
______________________________________________
[454] Fire Alarm Restore
Default (Fire Alarm Restore)
______________________________________________
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tl2803g3g2080rTl2803gr

Table of Contents