CPUs, Memory Cards, Memory Submodules, Interface Submodules
Jumper Settings
When the submodule is delivered, the jumpers are set as shown in the
on the
following figure. As a rule, therefore, you can use the RS 422 A/485
RS422 A/485
submodule immediately.
Submodule
Figure 5-26
With the jumpers on the switch row X3 you can remove the preset for
recognizing a break state from the two-wire line R.
When delivered, the two-wire line R is preset with the jumpers 12-14 and 4-6
so that the break state can be recognized. Pin 4 (R(A)) of the front connector
lies above a resistance on +5 V. Pin 11 (R(B)) of the front connector lies
above a resistance on ground.
If you replug the jumpers on 10-12 and 6-8, the two-wire line R is preset as
follows: pin 4 (R(A)) of the front connector lies above a resistance on
ground. Pin 11 (R(B)) of the front connector lies above a resistance on +5 V.
The break state cannot be recognized.
5-114
Front Connector
19
20
11
1
X4
12
2
RS422-A/485 Submodule: Jumper Settings when Delivered
1
X3
2
System Manual