RESTRICTED
AREA
Image 1-2
USA market
For LIPs (Laser Illuminated Projectors) installed in the USA market other restriction zone conditions apply.
Lip's for installation in restrained environment (cinema theaters) shall be installed at height vertically above the
floor such that the bottom plane of the hazard distance zone shall be no lower than 2.5 meters above the floor.
Horizontal clearance to the hazard distance zone shall be not less than 1 meter.
Lip's for installations in unrestrained environment (large venues,..) shall be installed at a height vertically
above the floor such that the bottom plane of the Hazard distance Zone shall be no lower than 3 meters above
the floor. Horizontal clearance to the hazard distance zone shall be not less than 2.5 meters. Any human
access horizontally to the Hazard Zone, if applicable, shall be restricted by barriers. If human access is
possible in an unsupervised environment, the horizontal or vertical clearances shall be increased to prevent
exposure to the hazard distance zone.
In addition for temporary installations (e. g.: rental and staging, lease, events ...) the following requirements
apply:
This product can only be installed by Barco or sold or leased only to valid laser light show variance holders.
In other words our installers are required to have an approved laser light show variance. Such installers
may currently hold a valid variance for production of Class IIIb and IV laser light shows and/or for
incorporation of the RG3 LIPs into their shows. Dealers and distributors are also required to obtain a valid
laser light show variance.
This product shall be located in such a way that all propagating beam paths within the Restriction Zone,
and the audience can be directly observed at all times.
Effects other than front or rear screen projections shall not be performed.
Communication shall be maintained with other personnel assisting in surveillance of the LIP projection.
In the event of any unsafe condition, immediately terminates (or designate the termination) of LIP
projection light.
Install one or more readily accessible controls to immediately terminate LIP projection light. The power input at
the projector side is considered as a reliable disconnect device. When required to switch off the projector,
disconnect the power cord at the projector side. In case the power input at the projector side is not accessible
(e. g. truss mount), the socket outlet supplying the projector shall be installed nearby the projector and be
easily accessible, or a readily accessible general disconnect device shall be incorporated in the fixed wiring.
Laser light shows can be requested via the FDA online eSubmitter portal or via FDA Form FDA Form 3147