IDI
IMMEDIATE DATA INPUT
Data file offset
232
Length
10
Destination
N11:232
AB Drives
In the previous example, an IDI is initiated that updates the
destination file from the private buffer before the next normal
input-image update. The Data File Offset (232) is the offset into the
buffer where the data is stored. The Length (10) identifies the number
of words in the transfer—it can be an immediate value ranging from 1
to 64 or a logical address that specifies the number of words to be
transferred. The Destination (N11:232) is the destination of the words
to be transferred. The Destination should be the matching data table
address in the DIF except when you use the instruction to ensure
data-block integrity in the case of Selectable Timed Interrupts (STIs).
See page 4-9.
Data Table
N11:0
N11:232
Programming Your ControlNet System
Private DIF Buffer
0
232
IDI copies from
the private DIF
buffer to the
data table
1785-UM022B-EN-P - February 2002
4-7
Inputs arrive from
the ControlNet
network