7. Specifications
.
Kipp & Zonen reserves the right to make changes to specifications and other product documentation without prior notice.

7.1 Optical and electrical

Specifications
Classification to ISO 9060:1990
Analogue output • V-version
Analogue output range*
Analogue output • A-version
Analogue output range*
Serial output
Serial output range
Response time
(63 %)
Response time
(95 %)
Spectral range
(20 % points)
Spectral range
(50 % points)
Zero o sets
(unventilated)
thermal radiation
(a)
(at 200 W/m )
temperature change
(b)
(5 K/h)
Non-stability
(change/year)
Non-linearity
(100 to 1000 W/m )
Directional response
(up to 80 ° with 1000 W/m beam)
Temperature response
Spectral selectivity
(350 to 1500 nm)
Tilt response
(0 ° to 90 ° at 1000 W/m )
Field of view
Accuracy of bubble level
Power consumption
(at 12 VDC)
Supply voltage
Detector type
Operating and storage temperature range
Humidity range
MTBF
**
(Mean Time Between Failures)
Ingress Protection (IP) rating
So ware, Windows™
* adjustable with Smart Explorer So ware
** extrapolated a er introduction in January 2012
Note: The performance specifications quoted are worst-case and/or maximum values

7.2 Dimensions and weight

Ø32 mm
Ø110 mm
SMP3
Weight without cable: 0.3 kg
SMP3
SMP6
Second Class
First Class
0 to 1 V
0 to 1 V
-200 to 2000 W/m
-200 to 2000 W/m
4 to 20 mA
4 to 20 mA
0 to 1600 W/m
0 to 1600 W/m
RS-485 Modbus®
RS-485 Modbus®
-400 to 2000 W/m
-400 to 2000 W/m
< 1.5 s
< 1.5 s
< 12 s
< 12 s
285 to 3000 nm
270 to 3000 nm
300 to 2800 nm
285 to 2800 nm
< 15 W/m
< 10 W/m
< 5 W/m
< 4 W/m
< 1 %
< 1 %
< 1.5 %
< 1 %
< 20 W/m
< 15 W/m
< 2 %
< 1.5 %
(-20 °C to +50 °C)
(-20 °C to +50 °C)
< 4 %
< 3 %
(-40 °C to +70 °C)
(-40 °C to +70 °C)
< 1 %
< 1 %
< 1 %
< 1 %
180 °
180 °
< 0.2 °
< 0.1°
V-version: 55 mW
V-version: 55mW
A-version: 100 mW
A-version: 100 mW
5 to 30 VDC
5 to 30 VDC
Thermopile
Thermopile
-40 °C to +80 °C
-40 °C to +80 °C
0 to 100 %
0 to 100 %
> 10 years
> 10 years
67
67
Smart Sensor Explorer So ware, for configuration, test and data logging
Ø50 mm
Ø150 mm
Ø150 mm
SMP's (except SMP3 and SMP11)
Weight without cable: 0.6 kg
SMP10 and SMP11
Secondary Standard
0 to 1 V
-200 to 2000 W/m
4 to 20 mA
0 to 1600 W/m
RS-485 Modbus®
-400 to 4000 W/m
< 0.7 s
< 2 s
270 to 3000 nm
285 to 2800 nm
< 7 W/m
< 2 W/m
< 0.5%
< 0.2%
< 10 W/m
< 1 %
(-20 °C to +50 °C)
< 2 %
(-40 °C to +70 °C)
< 1 %
< 0.2 %
180 °
< 0.1 °
V-version: 55mW
A-version: 100 mW
5 to 30 VDC
Thermopile
-40 °C to +80 °C
0 to 100 %
> 10 years
67
SMP11
Weight without cable: 0.6 kg
33
SMP21
SMP22
Secondary Standard
Secondary Standard
0 to 1 V
0 to 1 V
-200 to 2000 W/m
-200 to 2000 W/m
4 to 20 mA
4 to 20 mA
0 to 1600 W/m
0 to 1600 W/m
RS-485 Modbus®
RS-485 Modbus®
-400 to 4000 W/m
-400 to 4000 W/m
< 0.7 s
< 0.7 s
< 2 s
< 2 s
270 to 3000 nm
210 to 3600nm
285 to 2800 nm
250 to 3500 nm
< 7 W/m
< 3 W/m
< 2 W/m
< 1 W/m
< 0.5%
< 0.5%
< 0.2 %
< 0.2%
< 10 W/m
< 5 W/m
< 0.3%
< 0.3%
(-20 °C to +50 °C)
(-20°C to +50 °C)
< 0.3%
< 0.3%
(-40 °C to +70 °C)
(-40 °C to +70 °C)
< 1 %
< 2 %
< 0.2 %
< 0.2 %
180 °
180 °
< 0.1 °
< 0.1 °
V-version: 55mW
V-version: 55mW
A-version: 100 mW
A-version: 100 mW
5 to 30 VDC
5 to 30 VDC
Thermopile
Thermopile
-40 °C to +80 °C
-40 °C to +80 °C
0 to 100 %
0 to 100 %
> 10 years